A novel arc signal and motor power synchronization-based method for precise contact fault diagnosis of GIS
Song He1, Jiangjun Ruan2, Yufei Liu1
1Hubei Key Laboratory of Power Equipment & System Security for Integrated Energy, School of Electrical Engineering and Automation, Wuhan University, Wuhan, 430000, Hubei Province, China.
Abstract:
Gas-insulated switchgear (GIS) disconnectors play an important role in power systems, and their mechanical condition is critical for operational reliability. However, existing diagnostic methods frequently fail to accurately identify critical operational states during switching processes, such as the initial contact and separation points. This study proposes a novel diagnostic approach that combines arc signal detection and motor power analysis to address these limitations. The arc signal captured by a Rogowski coil provides precise timing information for contact engagement and separation. An adaptive wavelet packet decomposition method, guided by power spectral entropy, is used to effectively denoise the arc signal, allowing for precise extraction of ignition and extinction points. By synchronising the arc signal with motor power data, the proposed method makes it easier to diagnose common mechanical faults such as refusal to close, refusal to open, insufficient overtravel, and insufficient opening distance. Experimental validation confirms the method's robustness and reliability, emphasising its potential for improving GIS disconnector fault diagnosis and system reliability.
More Related Videos
10:52Design, Instrumentation and Usage Protocols for Distributed In Situ Thermal Hot Spots Monitoring in Electric Coils using FBG Sensor Multiplexing
Published on: March 8, 2020
08:55Use of a Foot-Induced Digitally Controlled Resistance Device for Functional Magnetic Resonance Imaging Evaluation in Patients with Foot Paresis
Published on: July 7, 2023
Related Concept Videos
Reclosers and Fuses
A comprehensive protection scheme for radial distribution...
Three-Phase Short Circuit—Unloaded Synchronous Machine
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
Power System Three-Phase Short Circuits
Line Protection with Impedance Relays
Under normal conditions, low load currents keep the measured...
Directional Relays
Bus Impedance Matrix
In the first circuit, all machine voltage sources are short-circuited, leaving only the prefault voltage source at the fault location. The positive-sequence bus impedance matrix can be determined by solving the nodal equations,...