Related Experiment Video
Updated: Apr 11, 2026

Ubiquitin Chain Analysis by Parallel Reaction Monitoring
Published on: June 17, 2020
Rapid Analysis of Urinary AICAR by Liquid Chromatography-Isotope Ratio Mass Spectrometry
Michael Polet1, Peter Van Eenoo1
1Doping Control Laboratory, Department of Diagnostic Sciences, Ghent University, Ottergemsesteenweg 460, BE-9000 Gent, Belgium.
Abstract:
5-Aminoimidazole-4-carboxamide-1-β-d-ribofuranoside (AICAR) is prohibited in sports according to the World Anti-Doping Agency (WADA). Currently, AICAR concentrations are measured during the initial testing procedure, and urine samples showing elevated levels are flagged as suspicious and forwarded for confirmation. Here, gas chromatography combustion isotope ratio mass spectrometry (GC-C-IRMS) is employed to distinguish endogenous from exogenous AICAR, as synthetic AICAR exhibits a different carbon isotope ratio (CIR). However, a GC-C-IRMS method comes with multiple challenges as AICAR is very polar, making it particularly difficult to analyze using GC. It is clear that there are a number of issues related to the existing protocol, and efforts should be made to develop new, more effective, and less expensive approaches. For polar substances, liquid chromatography-isotope ratio mass spectrometry (LC-IRMS) provides a more straightforward approach. There is no need for derivatization, AICAR can be directly analyzed with LC-IRMS, and many GC-C-IRMS related issues are avoided. LC-IRMS also allows condensing of the workflow and lowering of the turnaround time. In this study, a rapid protocol for AICAR CIR determination was developed, employing solid-phase extraction and 2D-LC cleanup prior to LC-IRMS analysis. Etiocholanolone and androsterone were used as endogenous reference compounds, and the method was fully validated according to WADA regulations. Reference population (n = 50) thresholds, used to declare an adverse analytical finding (AAF, i.e., a positive AICAR sample), were determined (6.9‰ and 5.8‰ for AICAR-etiocholanolone and AICAR-androsterone, respectively) and found to be approximately 2‰ lower than those previously reported using GC-C-IRMS, facilitating AAF identification.
More Related Videos
08:41Integration of Miniaturized Solid Phase Extraction and LC-MS/MS Detection of 3-Nitrotyrosine in Human Urine for Clinical Applications
Published on: July 14, 2017
10:17High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
Related Concept Videos
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...
Ion-Exchange Chromatography
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...