Related Experiment Video
Updated: Apr 11, 2026

Low-Cost, Volume-Controlled Dipstick Urinalysis for Home-Testing
Published on: May 8, 2021
The accuracy of a 4-item hydration self-assessment model to classify urine concentration using different cut-offs
Floris C Wardenaar1, Kinta D Schott1, Ryan G N Seltzer1
1College of Health Solutions, Athleat Field Lab, Arizona State University, 425 N. 5th Street, Phoenix, AZ 85004 USA.
Background:
Hydration is important for health and performance, but accurate self-assessment methods for active populations are limited. The study objective was to determine a model to classify by self-assessment a low vs. high 24-hour urine concentration, and to determine the accuracy of morning vs. afternoon assessments. The study describes the development and validation of a self-assessment model through exploratory modeling, using stepwise logistic regression. The aim was to determine which hydration markers predict urine specific gravity (using two different USG cut-offs: low ≤ 1.012, and high ≥ 1.020), in two intentionally overlapping 24-hour urine collections leading up to a morning and afternoon hydration self-assessment, and to assess its diagnostic accuracy based on the area under the curve (AUC).
Results:
A total of of n = 62 wildland firefighters (WLFFs), and n = 23 recreational athletes (12% female, median age 25 years, with interquartile range of 24-32) were included. The median USG values of the 24-hour urine collections leading up to the morning and afternoon assessments, were 1.011 and 1.012, respectively. The AUC for the final model, which included self-reported fluid intake; urine frequency, volume, and color, to classify low vs. high USG, for low cut-off (≤ 1.012) was fair in the morning (0.72), and good in the afternoon (0.85), and for high cut-off (≥ 1.020) good for morning (0.81) and afternoon (0.86), respectively.
Conclusion:
This 4-item hydration self-assessment model classifies a low vs. high USG acceptable, with slightly higher accuracy in the afternoon. This insight may inform targeted hydration monitoring strategies in occupational settings, for example among WLFFs.
Supplementary Information:
The online version contains supplementary material available at 10.1186/s44410-026-00024-y.
More Related Videos
10:21Evaluation of Hydration Status by Bioelectrical Impedance Vector Analysis in Patients with Ischemic Heart Disease Undergoing Exercise Stress Test
Published on: September 22, 2023
04:33Author Spotlight: Engineering Molecular Tools for Disease Detection and Imaging
Published on: December 8, 2023
Related Concept Videos
Urine Studies I: Urinalysis
Physiology of the Genitourinary System III: Urine Concentration and Dilution
Regulation of Water Intake
Formation of Dilute Urine
Filtrate Osmolarity in the PCT
Initially, as the filtrate passes through the proximal convoluted tubule (PCT), its...
Serum Studies: Renal Function Tests
Urine: Physical and Chemical Properties