Related Experiment Video
Updated: Apr 11, 2026

X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging
Published on: September 11, 2011
Enhanced X-ray image denoising via the synergy of linear attention and convolution
Yue Fei1, Xiaolong Zheng1, Wangyang Tong1
1College of Electronics and Information, Hangzhou Dianzi University, No. 1158, Ave. 2, Qiantang District, Hangzhou, 310018, Zhejiang, China.
Abstract:
X-ray imaging technology, as the core non-invasive inspection method, plays an irreplaceable role in industrial non-destructive testing and medical diagnosis. However, during signal acquisition, the imaging system faces multiple interferences, such as the quantum effect and electronic noise. This leads to a significant decrease in the image's signal-to-noise ratio, seriously affecting the accuracy of hazardous material identification and lesion detection. Existing X-ray image denoising methods have two major limitations. First, in physical model-driven denoising methods, the existing noise models deviate significantly from realistic ones, resulting in poor denoising results. Second, in mainstream deep learning-based methods, Convolutional Neural Networks (CNNs) have limitations in capturing long-range dependencies, while the Transformer model with a global receptive field has high computational complexity. To address these challenges, a physically grounded noise model is designed for synthesizing realistic X-ray images, trained on the public mainstream X-ray image security inspection datasets and augmented with hybrid real-synthetic data. Based on this, a novel denoising model, XDenoiser, is proposed in this paper. It incorporates a linear attention complexity Receptance Weighted Key-Value (RWKV) into a Transformer-based image restoration structure and combines it with CNNs to support both global and local receptive fields. Experiments on the expanded mainstream X-ray image security inspection datasets demonstrate the reasonableness and effectiveness of the XDenoiser algorithm.
Related Concept Videos
X-ray Imaging
Deconvolution
Deconvolution involves several mathematical techniques to derive the impulse response. One common approach is polynomial division. In this method, the input and output sequences are treated as coefficients of...
Super-resolution Fluorescence Microscopy
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Nuclear Overhauser Enhancement (NOE)
Convolution Properties II
The width property indicates that if the durations of input signals are T1 and T2, then the width of the output response equals the sum of both durations, irrespective of the shapes of the two functions. For instance, convolving two rectangular pulses with durations of 2 seconds and 1 second results in a function with a width of 3 seconds.
The area property asserts that the area under the...