Related Experiment Video
Updated: Apr 14, 2026

Registered Bioimaging of Nanomaterials for Diagnostic and Therapeutic Monitoring
Published on: December 9, 2010
Investigating the Sensitivity of the Diffusion MRI Signal to Magnetization Transfer and Permeability via Monte-Carlo
Zhiyu Zheng1, Karla L Miller1, Benjamin C Tendler1
1Oxford Centre for Integrative Neuroimaging (OxCIN), FMRIB, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, Oxfordshire, UK.
Purpose:
Magnetization transfer (MT) and water exchange via permeability operate on a similar spatiotemporal scale to water diffusion. In this study, we use a simulation-based approach to characterize how MT and permeability impact (1) diffusion-weighted MRI (dMRI) measurements from cylindrical substrates and (2) parameter estimation using a two-compartment model of white matter.
Methods:
We used Monte-Carlo simulations to model the dMRI signal inside and outside axons by simulating signals from parallel cylinders with different diameters and volume densities. We subsequently introduced membrane permeability and MT at the cylinder walls to investigate their impact on the dMRI signal. We fitted a two-compartment model to the simulated signal to produce estimates of the cylinder diameter and density. We evaluated the impact of MT and permeability by comparing the fitted diameter and density to the simulated ground truth.
Results:
Permeability leads to underestimation (up to 100%) of cylinder diameter and density. Specifically, by enabling isochromats to escape from restrictions and diffuse more freely, permeability makes the overall displacement profile closer to the extra-axonal displacement profile. MT had limited effects on diameter estimation but caused substantial bias (20%-50%) in volume density estimates depending on the ratio of the intra-axonal and extra-axonal volume fraction. This is due to the intra-axonal and extra-axonal space having different surface-to-volume ratios and therefore different surface relaxation rates.
Conclusion:
Permeability and MT can considerably influence the dMRI signal. They increase the relative contribution from larger cylinders to the dMRI signal and bias microstructural parameter estimates derived from dMRI data.
Related Concept Videos
Magnetic Resonance Imaging
Magnetic Susceptibility and Permeability
When diamagnetic materials are placed under an external magnetic field, the moments opposite to the field are induced. Hence, the susceptibility for diamagnets has a minimal negative value of 10-5–10-6. Since...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...