Related Experiment Video
Updated: Apr 14, 2026

Ultrasensitive Detection of Biomarkers by Using a Molecular Imprinting Based Capacitive Biosensor
Published on: February 16, 2018
Ultrasensitive Determination of Artificial Sweeteners in Environmental Water Samples Through Capillary
Yu-Ming Chou1, Ming-Mu Hsieh1, Wen Ting Yeh1
1Department of Chemistry, National Kaohsiung Normal University, Kaohsiung, Taiwan.
Abstract:
A dual-enrichment method based on efficient sample cleanup offline ion-pair ultrasonic surfactant-assisted dispersive liquid-liquid microextraction coupled with efficient sample stacking through online field-amplified sample stacking was devised for the concurrent determination of three artificial sweeteners (acesulfame potassium, saccharin, and cyclamate) using capillary electrophoresis (CE) coupled with capacitively coupled contactless conductivity detection. Various parameters that affected the CE separation performance and the enrichment efficiency of ion-pair ultrasonic surfactant assisted dispersive liquid-liquid microextraction and field-amplified sample stacking were optimized, and excellent CE separation was attained within 20 min. The optimal ion-pair ultrasonic surfactant-assisted dispersive liquid-liquid microextraction method used 240 µL of chlorobenzene as the extraction solvent, 125 µM N-methyl-N, N-dioctyloctan-1- ammonium chloride as the surfactant, and a pH of 7. Sample stacking was achieved by field amplified sample stacking in a 65 mM butyric acid buffer (pH 2.95), and the signal was detected by capacitively coupled contactless conductivity detection (2 Vpp, 200 kHz). Under the optimized conditions, the proposed method achieved enrichment factors ranging from 3158 to 3261. The linear concentration range was found to be 0.3-30 nM (r > 0.9993). The limits of detection for the three artificial sweeteners were in the range of 0.092-0.095 nM. Good precision was verified by the low relative standard deviations for migration times (3.0%) and peak areas (9.0%). The method was successfully applied to spiked environmental water samples. The relative errors for accuracy ranged from -3.4% to 7.5% for lake water, -8.8% to -0.3% for river water, and -6.8% to 9.6% for groundwater. Consequently, this method represents an efficient, rapid, and low-cost technique for extracting and determining artificial sweeteners in environmental water matrices.
More Related Videos
09:51TD-DFT Guided Advanced E-Eye Sensing Technique for On-site Quantification of Fe, Cr, F, and As in the Environmental, Biological, and Food Samples
Published on: September 19, 2025
07:26A Simple Method for Automated Solid Phase Extraction of Water Samples for Immunological Analysis of Small Pollutants
Published on: January 1, 2016
Related Concept Videos
Capillary Electrophoresis: Instrumentation
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Electrophoresis: Overview
There...
High-Performance Liquid Chromatography: Types of Detectors