Effects of Mechanical Methods Used in Peri-implantitis Treatment on Implant Surface Decontamination and Roughness
Published on: March 14, 2025
Effect of Material, Sterilization, and Repeated Use on the Deviations of PEEK and Titanium Monoblock Scanbodies
Bige Koc Ata1, Deniz Sen2, Fusun Ozer3
1PhD Student, Istanbul University, Institute of Graduate Studies in Health Sciences, Department of Prosthodontics, Istanbul, Turkey.
Objective:
The study aimed to evaluate the effects of multiple sterilization cycles and repeated clinical use on the stability of monoblock titanium and PEEK scanbodies.
Materials And Methods:
Ten monoblock titanium and PEEK scanbodies were paired up, thus forming a total of ten study groups. Each pair was scanned using an intraoral scanner to record a reference scan. Study groups underwent 30 cycles of tightening, loosening and sterilization, respectively. Scanning was performed after every five cycles, resulting in six study scans per group. Linear (∆X, ∆Y and ∆Z-axis), angular (∆ANGLE) and three-dimensional (Euclidean distance, ∆EUC) deviations were calculated and compared using two-way ANOVA test.
Results:
The number of repeated cycles was insignificant on scanbody deviations for both of the scanbody materials (p>0.05). The scanbody material had a significant impact, with titanium scanbodies demonstrating significantly higher deviations in ∆X, ∆Z and ∆EUC compared to PEEK scanbodies (p<0.05).
Conclusion:
PEEK scanbodies provided more accurate and more consistent digital scans than titanium.