High-speed Video Microscopy Analysis for First-line Diagnosis of Primary Ciliary Dyskinesia
Published on: January 19, 2022
Cilia Dynamics in Primary Ciliary Dyskinesia: A Biophysical Characterization of the RSPH4A Founder Variant
Gabriel Rosario-Ortiz1, José Muñiz-Hernández2, Natalia M Ortiz-Pérez1
1Department of Pediatrics and Basic Science, Ponce Health Sciences University, Ponce, PR 00716, USA.
Abstract:
Primary ciliary dyskinesia (PCD) is a rare ciliopathy resulting in chronic oto-sino-pulmonary disease. PCD diagnosis can be achieved by a combination of different diagnostic and adjuvant tools, including high-speed video-microscopy analysis (HSVA). A founder variant has been described in Puerto Rico as the most common cause of PCD in the island.
Background/Objectives:
In HSVA, objective parameters such as ciliary beat frequency (CBF) and subjective parameters such as ciliary beat pattern (CBP) shed light on the biophysical properties of cilia. However, the subjective nature of CBP creates a gap in knowledge; characteristics such as the length, angle, and bending index of cilia are poorly described. Our goal is to quantify cilia dynamics of the RSPH4A (c.921+3_921+6delAAGT (intronic)) founder variant in Puerto Rico through biophysical properties of cilia. This approach enhances longitudinal patient care by understanding treatment progress through biophysical ciliary function.
Methods:
We analyzed images from HSVA of six patients with PCD homozygous for the founder variant and six healthy controls (HC) (n = 12).
Results:
We found that ciliary length (PCD = 7.62 ± 0.95 μm, HC = 8.12 ± 1.36 μm, p = 0.204 ns), orientation vector (PCD = 7.20 ± 0.93 μm, HC = 7.25 ± 1.01 μm, p = 0.883 ns), straight angle (PCD = 1.67 ± 0.27 rad, HC = 1.76 ± 0.29 rad, p = 0.380 ns), and area (PCD = 2.35 ± 0.52 μm2, HC = 2.10 ± 0.53 μm2, p = 0.264 ns) did not have statistically significant differences between PCD and HC. In contrast, bending index (PCD = 1.06 ± 0.04, HC = 1.12 ± 0.09, p = 0.01), bent angle (PCD = 1.11 ± 0.30 rad, HC = 0.67 ± 0.21 rad, p < 0.0001), net angle (PCD = 0.56 ± 0.26 rad, HC = 1.09 ± 0.35 rad, p < 0.0001), amplitude (PCD = 5.77 ± 1.25 μm, HC = 7.99 ± 1.65 μm, p < 0.0001), and amplitude per second (PCD = 48.83 ± 13.23 A(s), HC = 91.66 ± 27.96 A(s), p < 0.0001) showed significant differences between both groups.
Conclusions:
Reduced angular excursion and amplitude in PCD demonstrate that the beating pattern of the RSPH4A founder variant is dysfunctional as compared with healthy controls. Our study provides an objective framework to understand the biophysical properties of the RSPH4A founder variant.
More Related Videos
09:03Nasal Brushing Sampling and Processing Using Digital High Speed Ciliary Videomicroscopy – Adaptation for the COVID-19 Pandemic
Published on: November 7, 2020
11:13Collection, Expansion, and Differentiation of Primary Human Nasal Epithelial Cell Models for Quantification of Cilia Beat Frequency
Published on: November 10, 2021
Related Concept Videos
Mechanism of Ciliary Motion
The cilia are made up of microtubules in a 9+2 arrangement, with nine microtubule doublet ring bundles, surrounding a pair of central singlet microtubule bundles. The doublet microtubule bundles are...
Mechanism of Ciliary Motion
Cystic Fibrosis: Pathogenesis
CF is primarily caused by a genetic mutation in a chromosome 7 gene coding for the cystic fibrosis transmembrane conductance regulator (CFTR) protein. The most common gene mutation leading to CF is the ΔF508 mutation,...
Microtubules in Signaling