Association Between Parameters of Penile Doppler Ultrasound and Cardiovascular Risk in Patients with Erectile
Andrea Graziani1,2, Andrea Delbarba3, Matteo Nardin4,5
1Department of Medicine, University of Padova, 35128 Padova, Italy.
Journal of Clinical Medicine
|April 14, 2026
Summary
Erectile dysfunction (ED) may signal early vascular disease. Penile Doppler ultrasound (PCDU) parameters correlate with cardiovascular risk, especially in younger men, aiding early risk assessment.
Area of Science:
- Cardiovascular Medicine
- Urology
- Vascular Imaging
Background:
- Erectile dysfunction (ED) is increasingly recognized as an early indicator of systemic vascular disease.
- Penile colour Doppler ultrasound (PCDU) offers quantitative vascular parameters.
- ED may serve as an early opportunity for cardiovascular risk assessment.
Purpose of the Study:
- To investigate the association between PCDU parameters and estimated cardiovascular risk in men with ED.
- To determine if PCDU can identify subclinical vascular impairment related to cardiovascular risk.
- To explore the role of PCDU in cardiovascular risk stratification for men with ED.
Main Methods:
- Retrospective observational study of 275 men undergoing PCDU for ED.
- Collected clinical data, biochemical markers, and QRISK3 cardiovascular risk scores.
- Analyzed peak systolic velocity (PSV), end-diastolic velocity (EDV), and resistive index (RI) using correlation and regression analyses.
Main Results:
- Impaired PSV (<35 cm/s) was linked to older age, higher QRISK3 scores, and more comorbidities.
- Mean PSV showed an inverse correlation with QRISK3 scores (r = -0.203, p < 0.01).
- Abnormal Doppler parameters correlated with increased cardiovascular risk, particularly in men aged 60 years or younger.
Conclusions:
- PCDU parameters reflect the overall cardiovascular risk burden in men with ED.
- Penile Doppler abnormalities may identify a vascular phenotype associated with higher cardiovascular risk, especially in younger men.
- These findings support comprehensive vascular assessment in selected patients with ED.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
3.0K
To obtain accurate blood pressure measurements in clinical settings, especially when traditional methods are insufficient, healthcare professionals utilize the Doppler ultrasound technique. This method uses high-frequency sound waves to detect blood flow within the arteries, which is crucial for patients with conditions that complicate circulatory system assessment.
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
3.0K
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
704
Clinical manifestationsPeripheral Arterial Disease (PAD) manifests through a range of symptoms, from the characteristic intermittent claudication to atypical presentations and severe complications in advanced stages. Intermittent claudication, a hallmark symptom of PAD, presents as exercise-induced muscle pain that typically resolves within minutes of rest. This pain is reproducible and stems from inadequate blood flow, leading to the accumulation of lactic acid produced during anaerobic...
704
Equipments Used To Measure Blood Pressure
4.0K
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
4.0K