Expedited Radiation Biodosimetry by Automated Dicentric Chromosome Identification ADCI and Dose Estimation
Published on: September 4, 2017
Determining EDC exposure: direct analytical methods are essential for accurate analysis of human biospecimens
Roy Gerona1, Alia Sovereign1, Deborah French2
1Department of Obstetrics, Gynecology, and Reproductive Sciences, University of California, San Francisco, CA 94134, USA.
Purpose:
Estimates of human exposure are a major component of chemical risk assessment. Studies of bisphenol A (BPA) have raised concern that exposure has been underestimated because the lack of standards for the measurement of the major BPA metabolites has necessitated the use of flawed analytical tools to indirectly estimate them. Because other endocrine-disrupting chemicals (EDCs) are measured using similar indirect methods, we evaluated the accuracy of indirect analysis for representatives from three different classes of non-persistent EDCs that undergo rapid phase II metabolism: bisphenols, parabens, and phthalates.
Methods:
A direct LC-MS/MS method that simultaneously measures bisphenol S (BPS), propyl paraben (PrP), and monobutyl phthalate (MBP), and their major metabolites in urine, was used to quantify these EDCs in sixty second-trimester human urine samples. The same samples were also analyzed with a widely used indirect method that requires enzymatic hydrolysis before estimating metabolite levels.
Results:
Marked discrepancies were evident when maternal urine samples were analyzed by both direct and indirect methods. Indirect analysis underestimated levels of all three EDCs and BPA, with the magnitude of underestimation varying by analyte.
Conclusion:
The accuracy of widely used "indirect" analytical methods that estimate metabolite levels in human urine is neither predictable nor consistent. Greater precision and accuracy is attained using authentic standards for metabolites. Given the importance of biomonitoring data in estimating human EDC exposure, analytical accuracy is critical. Availability of standards for both the parent compound and its major metabolites should be required before a chemical enters the marketplace.
More Related Videos
12:15Quantification of three DNA Lesions by Mass Spectrometry and Assessment of Their Levels in Tissues of Mice Exposed to Ambient Fine Particulate Matter
Published on: May 29, 2019
09:33Visualizing Field Data Collection Procedures of Exposure and Biomarker Assessments for the Household Air Pollution Intervention Network Trial in India
Published on: December 23, 2022
Related Concept Videos
EDTA: Direct, Back-, and Displacement Titration
Direct titration involves buffering the metal ion solution to the desired pH and directly titrating with standard EDTA until the endpoint. The optimum pH ensures a large conditional formation constant of metal−EDTA and visibility of the free indicator color in the solution. In addition, auxiliary complexing reagents are used to prevent the precipitation of metal hydroxides and...
Atomic Emission Spectroscopy: Overview