Uncovering the origin of impurities in supercritical fluid chromatography coupled to high-resolution mass
Azemina Bajramova1, Evangelos Synefakis2, Jesper Larsen3
1Lund University, Department of Chemistry, Centre for Analysis and Synthesis, P.O. Box 124 SE-22100, Lund, Sweden; AAK Denmark A/S, Slipvej 4,8000 Aarhus, Denmark.
Abstract:
Maintaining low background levels is essential for analytical instruments, such as in supercritical fluid chromatography (SFC) coupled to high-resolution mass spectrometry (HRMS). An approximate tenfold increase of the background was observed in our laboratory when a new CO2 cylinder with a dip tube was installed on a SFCHRMS system. Most analyte peaks were obscured. This study aimed to find the cause of the elevated background. Accordingly, the entire system was cleaned and each module, including the ion source, back pressure regulator, column, autosampler, solvent pumps, CO2 pump, and cylinder, were assessed. The troubleshooting suggested that the source of the contamination was the CO2 cylinder. A statistically significant (p < 0.05) elevation in the background was observed when liquid CO2 was used as mobile phase. The ions present above normal background levels were found to have m/z of 492.3439, 495.2934, 371.2434, and 490.3381. Annotation of the most abundant ion (m/z of 490.3381) based on m/z, isotope pattern, fragmentation pattern, and collision cross section, suggested structures resembling derivatives of sphingo- and glycolipids. A possible source could be degradation products formed during bioethanol production, the process from which the CO2 in the cylinder originates. Noteworthily, another SFCHRMS system that uses condensed gaseous CO2 instead of liquid CO2, has so far not resulted in any contamination-related issues. To prevent contamination in sensitive SFC-HRMS systems, it is essential to assess the purity of the CO₂ before use, especially if liquid CO2 from a cylinder with dip tube is used.
More Related Videos
11:00Untargeted Metabolomics from Biological Sources Using Ultraperformance Liquid Chromatography-High Resolution Mass Spectrometry UPLC-HRMS
Published on: May 20, 2013
07:103D Depth Profile Reconstruction of Segregated Impurities Using Secondary Ion Mass Spectrometry
Published on: April 29, 2020
Related Concept Videos
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
High-Resolution Mass Spectrometry (HRMS)