Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Electron Microscope Tomography and Single-particle Reconstruction01:07

Electron Microscope Tomography and Single-particle Reconstruction

2.0K
Transmission electron microscopy (TEM) can be used to determine the 3D structure of biological samples with the help of techniques such as electron microscope tomography and single-particle reconstruction. While single-particle reconstruction can examine macromolecules and macromolecular complexes in vitro conditions only, tomography permits the study of cell components or small cells in vivo.
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
2.0K
Mass Analyzers: Common Types01:19

Mass Analyzers: Common Types

1.9K
The quadrupole mass analyzer consists of four cylindrical metal rods arranged in a diamond carrying a DC voltage and a radio-frequency AC voltage. The motion of ions through the quadrupole depends on the field strength, causing only ions of a certain m/z to resonate successfully and strike the detector at a given field strength. Though the transmission rate for these analyzers is high, the exact elemental composition of the sample is not determined because of low resolution; however, they are...
1.9K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same journal

Compressed multi-scale entropy and its application in mechanical fault diagnosis.

The Review of scientific instruments·2026
Same journal

Bidirectional drive and multi-resolution adjustment across frequency bands in inertial impact piezoelectric motors via multimodal resonant vibration.

The Review of scientific instruments·2026
Same journal

A magnetic field sensor based on flaky Terfenol-D material and dual fiber grating.

The Review of scientific instruments·2026
Same journal

A novel E-field eight-way cavity combiner for high-power S-band applications.

The Review of scientific instruments·2026
Same journal

Constant radius blade spring suspended bench for vibration isolation.

The Review of scientific instruments·2026
Same journal

Qualification of infrared optical fibers and emitters for a spectrometer for in situ planetary exploration: Results from the TRIS (TRansmission and Illumination System) project.

The Review of scientific instruments·2026
See all related articles

Related Experiment Video

Updated: Apr 23, 2026

Measurement of X-ray Beam Coherence along Multiple Directions Using 2-D Checkerboard Phase Grating
10:39

Measurement of X-ray Beam Coherence along Multiple Directions Using 2-D Checkerboard Phase Grating

Published on: October 11, 2016

9.1K

4D beam matrix reconstruction in particle accelerators.

Nikolai Yampolsky1, Petr Anisimov1, Alexander Scheinker1

  • 1Los Alamos National Laboratory, Los Alamos, New Mexico 87545, USA.

The Review of Scientific Instruments
|April 21, 2026
PubMed
Summary
This summary is machine-generated.

This study introduces a new diagnostic method to fully characterize the four-dimensional (4D) transverse beam matrix in particle accelerators, overcoming limitations of traditional Twiss parameters for improved beam quality and performance.

More Related Videos

Quantification of Hydrogen Concentrations in Surface and Interface Layers and Bulk Materials through Depth Profiling with Nuclear Reaction Analysis
14:11

Quantification of Hydrogen Concentrations in Surface and Interface Layers and Bulk Materials through Depth Profiling with Nuclear Reaction Analysis

Published on: March 29, 2016

26.1K
Dynamic Pore-scale Reservoir-condition Imaging of Reaction in Carbonates Using Synchrotron Fast Tomography
10:18

Dynamic Pore-scale Reservoir-condition Imaging of Reaction in Carbonates Using Synchrotron Fast Tomography

Published on: February 21, 2017

9.0K

Related Experiment Videos

Last Updated: Apr 23, 2026

Measurement of X-ray Beam Coherence along Multiple Directions Using 2-D Checkerboard Phase Grating
10:39

Measurement of X-ray Beam Coherence along Multiple Directions Using 2-D Checkerboard Phase Grating

Published on: October 11, 2016

9.1K
Quantification of Hydrogen Concentrations in Surface and Interface Layers and Bulk Materials through Depth Profiling with Nuclear Reaction Analysis
14:11

Quantification of Hydrogen Concentrations in Surface and Interface Layers and Bulk Materials through Depth Profiling with Nuclear Reaction Analysis

Published on: March 29, 2016

26.1K
Dynamic Pore-scale Reservoir-condition Imaging of Reaction in Carbonates Using Synchrotron Fast Tomography
10:18

Dynamic Pore-scale Reservoir-condition Imaging of Reaction in Carbonates Using Synchrotron Fast Tomography

Published on: February 21, 2017

9.0K

Area of Science:

  • Particle accelerator physics
  • Beam dynamics
  • Advanced diagnostics

Background:

  • Traditional Twiss parameters for transverse beam description are limited as they ignore correlations between transverse coordinates.
  • These correlations, caused by magnetic field imperfections or misalignment, negatively impact beam quality and accelerator performance.

Purpose of the Study:

  • To develop and validate a novel diagnostic method for comprehensive four-dimensional (4D) transverse beam matrix reconstruction.
  • To address the limitations of existing methods in characterizing correlated beam dynamics.

Main Methods:

  • Utilizing a beamline with conventional and skew quadrupole magnets to generate distinct 2D projections of the 4D transverse phase space.
  • Measuring downstream 2D beam profiles for multiple quadrupole strength configurations.
  • Reconstructing the 4D beam matrix via an optimization-based least-square fit from the acquired projections.

Main Results:

  • Demonstrated accurate and robust reconstruction of the 4D transverse beam matrix through numerical simulations and particle-tracking.
  • Achieved reconstruction uncertainties smaller than measurement errors, especially with sufficient quadrupole scans.
  • Validated the diagnostic's flexibility across different beamline configurations.

Conclusions:

  • The proposed method offers a powerful and flexible approach for complete transverse beam characterization.
  • Enables precise accelerator tuning and performance optimization by providing full phase-space information.
  • Represents a significant advancement in particle beam diagnostics.