Enhancing mesenteric vascular imaging with dual-energy CTA: a comparison of DLIR and ASIR-V using low contrast agent
Yang Wu1,2,3, Juan Long1,2,3, Chenzi Wang1,2,3
1Department of Radiology, The Affiliated Hospital of Xuzhou Medical University, Xuzhou, Jiangsu, 221002, China.
Background:
Timely diagnosis of mesenteric vascular diseases, especially acute mesenteric ischemia (AMI) due to embolism in the superior mesenteric artery (SMA), is crucial for effective intervention. Dual-energy computed tomography angiography (DE-CTA) is a key diagnostic tool; however, concerns about contrast-induced nephropathy and radiation exposure persist.
Objectives:
This study assesses the diagnostic performance of DE-CTA for detecting mesenteric vascular diseases and compares the effectiveness of image reconstruction algorithms, specifically ASIR-V and DLIR, in enhancing image quality while minimizing the risks associated with contrast agents and radiation exposure.
Methods:
DE-CTA with virtual monoenergetic imaging (VMI) at 40 keV was performed on 50 patients. Image quality was evaluated using contrast-to-noise ratio (CNR), signal-to-noise ratio (SNR), and standard deviation (SD). The performance of DLIR and ASIR-V algorithms was compared, with an emphasis on minimizing radiation dose and contrast agent use through optimized low-dose protocols.
Results:
DLIR-H significantly outperformed both ASIR-V 50% and DLIR-M in terms of CNR and SNR, with CNR improving by 25% and SNR by 30% compared to ASIR-V 50%. DLIR-H also demonstrated superior noise reduction, with a 35% reduction in SD compared to ASIR-V. Furthermore, by effectively suppressing the elevated image noise inherent to low-dose scanning protocols, DLIR maintained excellent diagnostic image quality. This highlights its potential for dose reduction in clinical practice, which is crucial for minimizing the risks of radiation exposure and contrast-induced nephropathy.
Conclusion:
For mesenteric DE-CTA imaging at 40 keV, DLIR significantly improves objective image quality and subjective reader confidence compared to ASIR-V. By preserving fine vascular details at higher noise levels, DLIR demonstrates the potential to facilitate low-radiation and low-contrast-dose protocols in clinical practice.
More Related Videos
09:49Dual-phase Cone-beam Computed Tomography to See, Reach, and Treat Hepatocellular Carcinoma during Drug-eluting Beads Transarterial Chemo-embolization
Published on: December 2, 2013
07:14Dual Raster-Scanning Photoacoustic Small-Animal Imager for Vascular Visualization
Published on: July 15, 2020
Related Concept Videos
Imaging Studies VII: Vascular Imaging
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...