Related Experiment Video
Updated: Apr 25, 2026

An Integrated Raman Spectroscopy and Mass Spectrometry Platform to Study Single-Cell Drug Uptake, Metabolism, and Effects
Published on: January 9, 2020
Biophysical and Raman Spectroscopy assessment of drug-induced photosensitivity: Insights from a randomised controlled
Karolina Anderle1, Julia Deinsberger2, Pia Hübel3
1Department of Clinical Pharmacology, Medical University of Vienna, 1090 Vienna, Austria.
Background:
Drug-induced photosensitivity is a recognised adverse reaction, yet systematic quantification remains limited. This study investigates the quantitative impact of commonly prescribed drugs on human skin physiology following oral intake and subsequent UV exposure.
Methods:
Ten drugs with known photosensitising potential were selected: acetylsalicylic acid, amiodarone, diclofenac, doxycycline, enalapril, furosemide, hydrochlorothiazide, pantoprazole, verapamil, and voriconazole. Twelve healthy volunteers received five allocated substances, separated by washout periods. Defined skin areas were exposed to gradual UVA and UVB doses according to individual skin type. Skin parameters including confocal Raman spectroscopy (CRS), transepidermal water loss (TEWL), stratum corneum (SC) hydration, skin surface pH, melanin and erythema indices were measured 24 h after exposure.
Results:
Highest increase in erythema was caused by enalapril, amiodarone, furosemide and verapamil in response to both UVA and UVB irradiation. UVA predominantly increased melanin levels, while UVB caused pronounced erythema. No deterioration of natural moisturising factor or urea was observed throughout the entire analysed skin depth; TEWL remained unaffected. Trends towards increased SC hydration after irradiation were noted, but CRS analysis of minimal erythema dose skin sites did not reveal significantly increased water mass within the upper 30 µm of the skin. Average skin pH increase remained below 10%.
Conclusion:
The study underlines the need for standardisation of assessment tools for evaluating drug-induced photosensitivity, which complement visual evaluation. The marked interindividual variability across all skin parameters demonstrates the complexity of skin reactions.
More Related Videos
06:21Diffuse Optical Spectroscopy for the Quantitative Assessment of Acute Ionizing Radiation Induced Skin Toxicity Using a Mouse Model
Published on: May 27, 2016
07:05Correlative Optical Spectroscopy and Mass Spectrometry Imaging Methodology to Visualise Drug Distribution in a Soft Tissue Section
Published on: June 20, 2025
Related Concept Videos
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
Drug Toxicity: Allergic Reactions
Spectrophotometry: Introduction
The essential components of a spectrophotometer include a source of electromagnetic radiation, a slot for placing a material to be analyzed, and a...
Drug Toxicity: Dose-Dependent Reactions