Spreadsheet-based algorithm for objective assessment of depth of focus from defocus curves
Related Experiment Video
Updated: Apr 29, 2026

Digital Inline Holographic Microscopy DIHM of Weakly-scattering Subjects
Published on: February 8, 2014
Antonio Calossi1, Francesco Calossi, Riccardo Vinciguerra
1From the Department of Physics (Optics and Optometry), University of Florence, Florence, Italy (A. Calossi, F. Calossi); Humanitas San Pio X Hospital, Milan, Italy (R. Vinciguerra); Cullen Eye Institute, Baylor College of Medicine, Houston, Texas (Koch); IRCCS Humanitas Research Hospital, Milan, Italy (P. Vinciguerra).
Purpose:
To describe and clinically evaluate a spreadsheet-based algorithm for reproducible depth-of-focus (DoF) calculation, incorporating rule-based continuity detection derived from defocus-curve topology.
Setting:
Humanitas Clinical and Research Center, Rozzano, Milan, Italy.
Design:
Methodological description with retrospective clinical validation.
Methods:
The algorithm identifies dioptric crossings of a predefined logMAR threshold by locating bracketing points and applying linear interpolation. Validation involved analyzing defocus curves (-4.0 to +1.5 diopters [D] in 0.50-D steps) from monofocal pseudophakic eyes and comparing automated results with manual measurements by 2 experienced operators. Logic was implemented to classify continuous and discontinuous (multimodal) profiles and flag out-of-range data.
Results:
30 pseudophakic eyes implanted with monofocal intraocular lenses were included. DoF ranged from 1.10 to 3.17 D (mean 1.92 ± 0.47 D). Agreement between the algorithm and the 2 operators was high, with mean differences of -0.01 D (SD 0.08) and 0.00 D (SD 0.05), respectively. The interoperator difference was 0.01 D (SD 0.09). Mean absolute error was <0.05 D. Bland-Altman limits of agreement vs the operators' mean ranged from -0.10 to +0.09 D.
Conclusions:
The proposed method ensures objective and reliable DoF quantification by minimizing subjective interpretation and manual workload. Although clinical validation focused on monofocal profiles, the topology-based continuity logic provides a structured approach for analyzing complex curve profiles. A template spreadsheet is provided for implementation.