Flexural strength and fracture load of high-flow bulk-fill and conventional composites in ISO 4049 bars and MOD
Burcu Öztürk1, Elif Aslıhan Kahraman Karşıgil2, Fulya Aydın3
1Department of Restorative Dentistry, Faculty of Dentistry, Ankara University, Ankara, Türkiye. ozturkbrc93@gmail.com.
Background:
High-flow bulk-fill (HFB) resin composites have been introduced to simplify restorative procedures by enabling bulk placement and improved cavity adaptation. However, evidence is limited regarding whether their mechanical performance as stand-alone materials is consistent across different testing geometries. This study aimed to compare the flexural strength and fracture load of HFB composites with a conventional paste-like posterior composite using ISO 4049 bar specimens and MOD shaped restorations.
Methods:
Eighty specimens were fabricated and divided into two specimen configurations: ISO 4049 bar specimens (25 × 2 × 2 mm) and MOD shaped restorations (12 × 7 × 5 mm) (N = 40 each). Three HFB composites-Clearfil Majesty ES High Flow (CM), Tetric N Flow Bulk Fill (TF), and Estelite Universal High Flow (EU)-and one conventional paste-like posterior composite (GC G-aenial Posterior; GP) were tested (n = 10 per subgroup). ISO specimens were evaluated for flexural strength (MPa) and MOD specimens evaluated for fracture load (N) using a three-point bending and fracture load test at 1 mm/min. Data were analyzed using one-way ANOVA and Tukey post hoc tests (α = 0.05).
Results:
Remarkably, the mechanical outcomes varied depending on the tested composite material and the specimen configuration (p < 0.05). In MOD shaped restorations, TF demonstrated the highest fracture load (1198.33 ± 188.83 N), followed by EU (1007.76 ± 182.37 N), GP (871.92 ± 227.67 N), and CM (776.10 ± 93.06 N). In ISO 4049 bar specimens, EU exhibited significantly higher flexural strength (85.84 ± 23.43 MPa) compared with CM (61.76 ± 2.99 MPa), TF (55.27 ± 12.04 MPa), and GP (54.19 ± 11.57 MPa) (p < 0.05). Material ranking differed between ISO bar and MOD specimen configurations.
Conclusions:
HFB resin composites showed flexural strength and fracture load values comparable to or higher than those of the conventional paste-like posterior composite. However, performance was material-dependent and influenced by specimen geometry. These findings highlight the importance of combining standardized and geometry-dependent testing approaches for a more comprehensive evaluation of restorative materials.
More Related Videos
07:09In situ Compressive Loading and Correlative Noninvasive Imaging of the Bone-periodontal Ligament-tooth Fibrous Joint
Published on: March 7, 2014
11:28A Coupled Experiment-finite Element Modeling Methodology for Assessing High Strain Rate Mechanical Response of Soft Biomaterials
Published on: May 18, 2015
Related Concept Videos
Flexural Stress
Hooke's Law states that within the material's elastic limits, stress is directly proportional to strain. In a member experiencing a bending moment, the strain at any point is relative to its distance...
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...
Behavior of Concrete Under Compressive Load
As the concrete specimen fractures under...
Stress-Strain Diagram - Brittle Materials
Bending of Members Made of Several Materials
Hooke's Law determines stress in each material, stating that stress is proportional to strain but varies due to each material's...
Impact Strength of Concrete