Ventilation characteristics of cardiopulmonary resuscitation manikins: a mixed-methods bench study
David Purkarthofer1,2,3,4, Michael Weldi5,6, Gerald Trathnigg5,6
1Medical University of Graz, Neue Stiftingtalstraße 6, Graz 8010, Styria, Austria.
Background:
Sufficient ventilation during cardiopulmonary resuscitation (CPR) is increasingly recognised as a critical determinant of patient outcomes. The effectiveness of ventilation training, however, likely depends on the anatomical and mechanical fidelity of CPR manikins. While chest compression mechanics of manikins have been studied extensively, ventilation-related anatomy, airflow pathways, and respiratory mechanics have not been evaluated systematically.
Methods:
This study analysed 10 adult CPR manikins from three manufacturers. Airway and lung replicas were documented using photography, video laryngoscopy, and bronchoscopy. Expiratory tidal volume and air leakage were measured during volume-controlled mechanical ventilation via facemask, supraglottic airway devices and endotracheal tube. Mechanics of the respiratory system were described by the peak and plateau airway pressures and respiratory compliance.
Results:
Manikins differed substantially in airway design and expiratory airflow design. Three distinct expiratory mechanisms were identified, of which only one permitted exhalation through the airway and thus quantification of expiratory tidal volumes. Air leakage varied across manikins and airway devices, including during ventilation via advanced airway devices. Respiratory mechanics showed marked variability, with peak inspiratory pressures ranging from 21 ± 1 to 56 ± 1 mbar and compliances from 7 ± 0 to 51 ± 4 mL/mbar. Several models exhibited substantial leakage via the gastric channel of the i-gel® supraglottic airway.
Conclusion:
CPR manikins exhibited substantial variability in ventilation-related anatomy, airflow pathways, leakage and respiratory mechanics. None of the assessed manikins consistently approximated human ventilation characteristics across airway devices, underscoring the need for local evaluation of manikin-airway device combinations to optimise ventilation fidelity in CPR training.
Related Concept Videos
Cardiopulmonary Resuscitation II: ACLS Airway Management
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Mechanical Ventilation I: Indication and Settings
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...