Related Experiment Video
Updated: May 5, 2026

Voluntary Breath-hold Technique for Reducing Heart Dose in Left Breast Radiotherapy
Published on: July 3, 2014
Clinical Predictors of Dosimetric Precedence for Deep Inspiratory Breath Hold Radiation Therapy for Breast Cancer
Alzahra'a Al Matairi1, Abdulla Alzibdeh2, Issa Mohamad2
1Faculty of Medicine, The University of Jordan, Amman 11942, Jordan.
Abstract:
Background/Objectives: Radiation therapy for left-sided breast cancer exposes the heart and lungs to incidental radiation, increasing long-term risk of cardiopulmonary morbidity. This study evaluated the dosimetric impact of DIBH compared with free breathing (FB) and explored patient- and treatment-related predictors of benefit. Methods: We retrospectively analyzed 90 patients with left-sided breast cancer or chest wall irradiation planned under both FB and DIBH. Dosimetric parameters included mean heart dose (MHD), mean lung dose (MLD), heart V5, and lung V20. Univariable analyses assessed associations between dose reductions (Δ%) and clinical factors (age, BMI, fractionation, boost, nodal fields, and smoking). Multivariable regression identified independent predictors. Results: DIBH significantly reduced mean doses to the heart (FB 4.25 ± 1.47 Gy vs. DIBH 2.64 ± 1.28 Gy; Δ -1.60 Gy, p < 0.001, and Cohen's d = 2.46) and lung (FB 14.00 ± 3.45 Gy vs. DIBH 11.64 ± 3.32 Gy; Δ -2.36 Gy, p < 0.001, and Cohen's d = 2.73). Similarly, heart V5 (median Δ -10.5%, p < 0.001) and lung V20 (median Δ -5.5%, p < 0.001) were significantly improved. Higher BMI was independently associated with smaller relative reductions in MHD (-1.4% per unit, p < 0.001) and MLD (-0.31% per unit, p = 0.019). Hypofractionation was linked to greater MHD and MLD reductions (+8.9%, p = 0.007), (3.7%, p = 0.035), respectively. Supraclavicular field irradiation increased lung exposure, while internal mammary chain fields elevated both lung and heart doses. Age showed no significant influence. Conclusions: DIBH provides robust and consistent reductions in cardiac and pulmonary radiation doses during left-sided breast irradiation. The degree of sparing is modulated by BMI, fractionation, and nodal field inclusion.
Related Concept Videos
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...

