Analysis of Strength and Homogeneity of Different Concrete Specimens Prepared Under a High-Frequency and Low-Power
Nabi İbadov1, Gürcan Çetin2, Ercüment Güvenç3
1Faculty of Civil Engineering, Department of Production Engineering and Management in Construction, Warsaw University of Technology, Al. Armii Ludowej 16, 00-637 Warszawa, Poland.
Abstract:
Ensuring the durability and safety of modern infrastructure critically depends on the quality and strength of concrete. The Ultrasonic Pulse Velocity (UPV) method is a widely used non-destructive testing technique for evaluating concrete properties; however, factors such as aggregate size distribution, compaction methods, and surface quality can significantly influence UPV results and their correlation with compressive strength. This study investigates the effects of different aggregate sizes and an innovative vibration-assisted compaction method-developed using piezoelectric (PZT) transducers-on the mechanical, ultrasonic, and surface properties of concrete. Four distinct aggregate size distributions were employed to produce sixteen concrete specimens with constant mix proportions. Unlike conventional low-frequency, high-power vibration practices, a high-frequency (40 kHz), low-power (120 W) vibration protocol was applied through PZT elements placed within the molds to enhance compaction and reduce entrapped air. Experimental results indicated that the heaviest specimen (7.13 kg) was the medium-aggregate sample compacted using tamping and rodding methods. The highest UPV value (4143 m/s) was obtained from the coarse-aggregate specimen subjected to three minutes of vibration. In contrast, the best compressive strength performance (22.73 MPa) was observed in the medium-aggregate specimen without any vibration treatment. The findings revealed that both aggregate size and advanced vibration techniques have significant effects on the mechanical properties, ultrasonic response, and surface quality of concrete. In addition, a proof-of-concept portable surface-finishing prototype consisting of a steel plate instrumented with multiple PZT transducers was developed, and preliminary trials qualitatively suggested improved surface leveling when applied in contact with the concrete surface. Surface roughness was quantified via image processing (Light Map 150 and Specular Map 150). The rough-area fraction decreased from ~29.8% in the untreated specimen to ~4.3% after ultrasonic application, indicating a marked improvement in surface leveling and overall surface quality. The results indicate that the applied PZT vibration protocol did not improve compressive strength; in several cases, particularly under prolonged excitation, a reduction in strength was observed. In contrast, a significant improvement in surface quality was achieved, with the rough-area fraction decreasing from approximately 29.8% to 4.3%. However, due to the limited number of specimens, the findings should be interpreted as preliminary. Overall, the method appears more promising as a surface enhancement technique rather than a direct alternative to conventional compaction methods.
More Related Videos
07:02Investigating the Potential of Singly Curved Thin Piezoelectric Transducers for Energy Harvesting and Structural Health Monitoring
Published on: November 14, 2025
10:39Fabrication and Characterization of Thickness Mode Piezoelectric Devices for Atomization and Acoustofluidics
Published on: August 5, 2020
Related Concept Videos
Dynamic Modulus of Elasticity of Concrete
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by a...
Non-destructive Tests for Concrete Strength
Microcracking in Concrete
Behavior of Concrete Under Compressive Load
As the concrete specimen fractures under...
Impact Strength of Concrete
Fatigue Strength of Concrete