Related Experiment Video
Updated: May 5, 2026

Quantitative Visualization and Detection of Skin Cancer Using Dynamic Thermal Imaging
Published on: May 5, 2011
Clinical Thermography of the Diabetic Foot Using a Low-Cost Thermal Camera: Processing and Instrumental Framework
Vanéva Chingan-Martino1,2, Mériem Allali3, Stéphane Henri4
1Diabetic Foot Service, University Hospital, 97139 Les Abymes, Guadeloupe, France.
Abstract:
Infrared thermography is a non-contact tool for monitoring inflammatory processes in the diabetic foot, but quantitative bedside use remains challenging with low-cost thermal infrared cameras due to radiometric drift, non-uniformity (vignetting), geometric distortions, and visible-thermal parallax. This paper presents an end-to-end clinical and instrumental framework built around a cheap thermal camera to ensure reproducible acquisition and physically consistent temperature estimation. The approach combines a standardized mobile acquisition setup and measurement protocol, extraction of embedded radiometric data from raw images, radiometric inversion with atmospheric correction, vignette correction performed in the radiometric domain, and geometric calibration of both visible and infrared sensors using dedicated (thermal) calibration targets. Accurate visible-infrared registration is obtained from hybrid heated markers, enabling reliable overlay and downstream analysis. The full processing chain yields quantitative thermograms with radiometric errors below 0.15 °C and sub-pixel multimodal alignment, supporting the detection of clinically relevant plantar temperature asymmetries and paving the way for routine calibrated low-cost thermography in diabetic foot care.
Related Concept Videos
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Diabetic Foot Ulcer
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...