Related Experiment Video
Updated: May 5, 2026

Fiber Optic Distributed Sensors for High-resolution Temperature Field Mapping
Published on: November 7, 2016
Temperature Determination and Scene Change Artifact Mitigation When Using Fourier-Transform Spectroscopy on Targets
Kody A Wilson1, Michael L Dexter1, Benjamin F Akers1
1Center for Technical Intelligence Studies and Research, Air Force Institute of Technology, 2950 Hobson Way, Fairborn, OH 45433, USA.
None:
Fourier-transform spectroscopy is a widely used technique for determining the spectral and thermal properties of a target. However, target temperature variations during measurement can compromise the spectral accuracy. Temperature fluctuations induce oscillations superimposed on the target spectrum. These oscillations, referred to as scene-change artifacts, degrade the spectral accuracy. The literature is divided, with theoretical predictions suggesting negligible artifacts and growing experimental evidence reporting significant artifacts. This paper presents a theory and experimental validation of scene-change artifacts originating from target temperature variations. Traditionally, the interferogram offset is assumed to be constant, an invalid assumption for a changing scene. The error is subsequently Fourier-transformed, producing scene-change artifacts. Accurately estimating the truth spectrum is often challenging. To address this, we propose the signal-to-scene-change-artifact ratio, a metric that quantifies the impact of scene-change artifacts without knowledge of the truth spectrum. The artifacts will be eliminated by estimating the interferogram offset using smooth offset correction. Furthermore, the interferogram offset enables determination of the target's temperature with a greater accuracy and an increased temporal resolution compared to using the spectra. These results will demonstrate that a smooth offset correction can improve the spectrum and temperature accuracy on thermally variant targets when measured with a Fourier-transform spectrometer.
More Related Videos
10:03Proton Transfer and Protein Conformation Dynamics in Photosensitive Proteins by Time-resolved Step-scan Fourier-transform Infrared Spectroscopy
Published on: June 27, 2014
11:34Subsurface Defect Localization by Structured Heating Using Laser Projected Photothermal Thermography
Published on: May 15, 2017
Related Concept Videos
Atomic Spectroscopy: Effects of Temperature
At thermal equilibrium, the relative populations of excited and ground state atoms can be estimated using the Maxwell–Boltzmann distribution. For example, an increase in temperature...
IR Spectrometers
Discrete Fourier Transform
Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview
The ATR process begins by directing a beam...
Continuous -time Fourier Transform
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...