Tear Dynamics During Fenestrated Scleral Lens Wear: A Pilot Study
Damien Fisher1, Asif Iqbal1, David Alonso-Caneiro1,2
1Contact Lens and Visual Optics Laboratory, Optometry and Vision Science, Centre for Vision and Eye Research, Queensland University of Technology, Brisbane, Queensland, Australia.
Summary
A new Scheimpflug imaging technique quantifies tear exchange in fenestrated scleral lenses. Two tear flow patterns were identified, with low flow linked to increased corneal edema.
Area of Science:
- Ophthalmology
- Biomedical Engineering
- Contact Lens Technology
Background:
- Scleral lenses create a fluid reservoir between the lens and cornea.
- Understanding tear dynamics within this reservoir is crucial for optimizing lens design and patient outcomes.
- Current methods for assessing tear exchange are limited.
Purpose of the Study:
- To develop and validate a Scheimpflug-based image analysis technique for quantifying tear exchange.
- To investigate tear fluid reservoir dynamics in fenestrated scleral lens wear.
Main Methods:
- Nine healthy participants wore a fenestrated scleral lens for 90 minutes.
- Scheimpflug images were captured after sodium fluorescein application to assess tear mixing.
- Corneal edema was measured using optical coherence tomography.
Main Results:
- The developed technique showed good repeatability for measuring fluid reservoir intensity.
- Tear fluid intensity varied spatially, being higher in the periphery.
- Two distinct tear dynamics patterns (low and high flow) were observed.
- Low flow was associated with increased corneal edema, though not statistically significant.
Conclusions:
- Tear exchange in fenestrated scleral lenses stabilizes within 10 minutes.
- The study identified two tear flow patterns, suggesting implications for corneal health.
- The developed Scheimpflug imaging technique offers a novel approach for studying tear dynamics in scleral lens wear.