Secure image transfer is a critical requirement in telemedicine and Picture Archiving and Communication Systems (PACS), where diagnostic integrity and patient confidentiality must be simultaneously ensured. High-resolution medical images, especially Magnetic Resonance Imaging (MRI), are often transferred over bandwidth-limited networks without impairing diagnostic quality or confidentiality against unauthorized access, manipulation, and replay. Existing approaches generally rely on a cascaded pipeline where image compression, encryption, and verification are considered as separate, independent operations. These distributed designs are prone to cryptographic key management issues, suffer from non-deterministic error control, lack meaningful coupling between image identity and cryptographic state, and provide no verifiable provenance or post-quantum key migration support. In this paper, we propose a DICOM-compliant system that integrates [Formula: see text]-regularized near-lossless image compression, hyperchaotic permutation diffusion encryption, post-quantum secure key establishment, and blockchain-based provenance verification as a unified operation. JPEG 2000 is used for primary image compression, and a residual refinement layer is introduced to limit residual correction amplitudes by [Formula: see text]-regularization to retain diagnostically significant information. Hyperchaotic encryption is performed with a symmetric image key generated using the NIST-standard post-quantum Key Encapsulation Mechanism (ML-KEM) and extracted using the HMAC-based Key Derivation Function (HKDF), cryptographically linked to DICOM image metadata. Message integrity is ensured using a keyed-hash message authentication code (HMAC), while a permissioned blockchain records only non-sensitive cryptographic metadata to enable verifiable provenance. Experimental results on clinical MRI and susceptibility-weighted imaging datasets demonstrate high reconstruction quality (PSNR: 46-51 dB, SSIM: 0.92-0.97), compression ratios ranging from 7.14:1 to 23.03:1 depending on modality and [Formula: see text], and strong cryptographic properties (NPCR: 99.6%, UACI: 33.46%, entropy: 7.9993). The evaluation focuses on MRI-based modalities, reflecting the intended scope of this study.
Related Concept Videos
Issues And Trends In Healthcare Delivery System
Cost Containment
Payment for healthcare services has historically promoted adoption of costly and often unnecessary or inefficient...
Ethical Standards I
The Code of Ethics provisions outline the nurse's duty to the patient, the healthcare team, the profession, and society. The Code's fundamental principles include advocacy,...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Legal Guidelines for Documentation