Ultrasonographic Evaluation of Breast Cancer-related Lymphedema
Published on: January 12, 2017
Diagnosing Lymphedema After Axillary Surgery: A Prospective Comparison of Bioimpedance, Tape Measurement, and
Andrea V Barrio1, Brian Diskin1, Bayley Axelrod1
1Breast Service, Department of Surgery, Memorial Sloan Kettering Cancer Center, New York, NY, USA.
Objective:
This study prospectively compared lymphedema rates with perometer, tape measure, and bioimpedance spectroscopy (L-Dex) in patients with breast cancer undergoing axillary lymph node dissection (ALND).
Background:
Perometer, tape measure, and L-Dex are all used for diagnosing lymphedema, although lymphedema rates may vary between these techniques.
Methods:
From November 2016 to March 2020, patients who underwent ALND had arm measurements performed preoperatively and biannually with perometer, tape measure, and L-Dex. A lymphedema diagnosis was made if arm volume increased by ≥10% by perometer or tape measure, or if L-Dex increased ≥6.5 units from baseline. We assessed concordance between the different measurement techniques using scatter plots, Pearson correlations, and Cohen's Kappa statistic.
Results:
We included 281 patients who underwent ALND and had at least one follow-up (median, 2.3 years; >1100 follow-up measurements). Two-year lymphedema rates were 21.9% with perometer, 34.6% with tape measure, and 67.5% with L-Dex. Evaluating all timepoints, we found moderate correlation between perometer and tape measure (R=0.67, P<0.001), perometer and L-Dex (R=0.66, P<0.001) and tape measure and L-Dex (R=0.57, P<0.001). Diagnostic agreement was weak between perometer and L-Dex (k=0.29, P<0.001), and tape measure and L-Dex (k=0.28, P<0.001); and moderate between perometer and tape measure (k=0.51, P<0.001).
Conclusion:
In our prospective ALND cohort, perometer, tape measure, and L-Dex demonstrated moderate correlation between measurements, and weak-to-moderate diagnostic agreement. Lymphedema rates varied between measurement techniques, with the highest rates observed with L-Dex, raising concern for overdiagnosis.
Related Concept Videos
Pre-Procedural Guidelines for Assessing Blood Pressure
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Peripheral Artery Disease V: Postoperative Nursing Management