Reliability of Artificial Intelligence-Based Cone Beam Computed Tomography Integration with Digital Dental Images
Published on: February 23, 2024
Acceptability, deviation, and efficiency of automated artificial intelligence-based implant planning methods: A
Satita Leelaluk1, Hanin Hammoudeh2,3, Suchada Kongkiatkamon4
1Advanced Prosthodontics Program, The Ohio State University College of Dentistry, Columbus, Ohio, USA.
Purpose:
To evaluate the acceptability, deviation, and efficiency of two automated, artificial intelligence-driven implant planning methods compared with a human-based approach for single-tooth replacement.
Materials And Methods:
Data of 32 patients, involving a single edentulous span, were retrospectively obtained, including cone-beam computed tomography (CBCT) and intraoral scans. Three implant planning methods were applied per case: human-based method (HP), automated CBCT-image-based method (AA), and automated CBCT-segmentation-based method (RL). Implant position acceptability was assessed by three prosthodontists using a standardized three-point scale on 12 surgical and prosthetic parameters. Using HP as a reference, angular and linear positional deviations were quantified at the implant platform and apex. Total planning time was recorded. Statistical analyses included Friedman's chi-square test, Wilcoxon test, ANOVA with Tukey's post hoc tests, and intraclass correlation coefficient (α = 0.05).
Results:
No significant differences were observed between RL and HP for most surgical and prosthetic parameters except for the crestal bone and platform-planned gingival margin distance. At the same time, AA showed significantly lower scores than both methods. No significant differences were found among the three methods for implant-mandibular canal distance. AA demonstrated significantly higher positional deviation than RL (p < 0.001). Total planning time differed significantly among methods. HP (14.1 ± 2.44 min), RL (8.91 ± 2.89 min), and AA (3.59 ± 1.44 min) with all pairwise comparisons significant (p < 0.001).
Conclusions:
Compared to HP, RL demonstrated similar surgical and prosthetic acceptability with faster planning time. AA was the most efficient but showed lower acceptability than both HP and RL, and demonstrated greater positional deviation than RL.