Related Experiment Video
Updated: May 16, 2026

Endotracheal Intubation via Tracheotomy and Subsequent Thoracotomy in Rats for Non-Survival Applications
Published on: March 15, 2024
Comparison of Adult Tracheostomy Outcomes Before and After Implementation of a Dedicated Tracheostomy Team
Trace T Palmer1, Cindy M Moore2, Kelsey L Bounds-Wood1
1Department of Otolaryngology - Head and Neck Surgery, University of Mississippi Medical Center, Jackson, MS, USA.
Objective:
(A) Determine patient and institutional factors associated with increased length of stay (LOS) and complications of tracheostomy, (B) Develop data-driven quality improvement in tracheostomy care.
Design:
Mixed methods protocol used cross-sectional survey assessing institutional trends in tracheostomy-specific care. Retrospective chart review compared tracheostomy patient outcomes prior to and during implementation of a multidisciplinary tracheostomy care team and standardized guidelines.
Participants:
Patients undergoing tracheostomy from January 2019 to December 2021 at a tertiary hospital.
Methods:
Patient factors, procedure type and indication, tracheostomy tube size, management timeline, insurance, and disease severity using Acute Physiology and Chronic Health Evaluation II (APACHE II) score were analyzed for associations with LOS and adverse events. Multivariate analyses controlled for APACHE II score and payer source. LOS and complications were compared between patients before and during implementation of multidisciplinary tracheostomy care team and standardized guidelines.
Results:
Three-hundred and eighteen patients met criteria with a 21.7% complication rate, average LOS of 24 days (SD = 28.523), and median LOS post-tracheostomy of 14 days (IQR 7, 29). Departments without standardized protocols had greater LOS (F[1,316] = 28.706, P < .001]) and complication odds (OR = 2.92, P = .015, 95% CI[1.231, 6.930]). Larger tracheostomy tube size was linked to increased LOS (β = .253, t(314) = 4.741, P < .001, 95% CI[4.137, 10.081]). Delays from ventilation discontinuation to cuffless tube exchange and decannulation correlated with increased LOS (β = .406, t(184) = 6.321, P < .001, 95% CI[.928, 1.771]); (β = .554, t(129) = 7.625, P < .001, 95% CI[1.008, 1.715]). When focusing on a single department, comparing 2019 patients to 2021 patients (pre- and post-guideline and care team), overall, LOS decreased from 33.08 to 30.83 days (P = .586). When excluding patients discharged on a ventilator, the 2019 group had average LOS of 37.938 days versus 33.41 days in 2021 (P = .344).
Conclusions:
Standardized tracheostomy care guidelines and multidisciplinary care teams are critical to improving institutional outcomes. Data-driven approaches to quality improvement ensure efficient and targeted methods to improving patient care.
Level Of Evidence:
4.
Related Concept Videos
Tracheostomy Care I: Pre-procedural Steps
Required Equipment
The equipment necessary for tracheostomy care includes:
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...
Tracheostomy Care II: Procedure
Step 1: Perform hand hygiene, and put on personal protective equipment: gown, gloves, mask and...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...