Pressor Response Index During Blood Return as a Marker for Identifying Intradialytic Hypotension
Ai Akazawa1, Shota Yoshizawa2, Takahito Ito3
1Satsukinomori Clinic, Hamamatsu, Japan.
Background:
Intradialytic hypotension (IDH) is a frequent complication of hemodialysis (HD). Although nadir blood pressure-based definitions are prognostically relevant, their use in daily practice is limited because accurate identification requires frequent blood pressure monitoring. Because blood pressure (BP) is routinely measured during HD, the magnitude of the systolic BP rise during blood return may provide a simple and practical marker for identifying IDH.
Methods:
This cross-sectional study was conducted at a single HD center. Study 1 evaluated factors associated with the pressor response index in 53 HD patients across 159 sessions using analysis of covariance (ANCOVA). Study 2 examined the ability of the index to discriminate HD sessions with and without IDH as defined by McCausland et al.
Results:
The pressor response index was significantly associated with maximum systolic BP drop and hypovolemic symptoms. The index clearly distinguished sessions with and without IDH. The effect size was large (Cohen's d = 1.41), and ROC analysis showed good discrimination (AUC 0.823). The optimal cut-off value was 10.3% (sensitivity 0.84, specificity 0.65).
Conclusion:
The pressor response index may represent a simple, objective, and practical marker for identifying IDH in routine clinical practice.
Related Concept Videos
Measurement of Blood Pressure
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Alterations in Blood Pressure
Hypertension (High blood pressure)
Hypertension occurs when blood pressure readings consistently exceed the normal range. It is diagnosed when systolic blood pressure (the top number, indicating pressure while the heart beats)...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of blood pressure in brachial artery(two-step method)