Related Experiment Videos
[Structural Evolution and Carbon Emission Reduction Path in China's Power Sector Based on LEAP-ABM Model]
Qin-Liang Tan1, Chao-Fan Shi1, Jian Han2
1School of Economics and Management, North China Electric Power University, Beijing 102206, China.
Huan Jing Ke Xue= Huanjing Kexue
|May 20, 2026
Summary
Achieving carbon neutrality requires coordinated power sector transitions. Dual high-speed demand and supply strategies best reduce emissions, while a fast demand-side transition alone may increase them.
Area of Science:
- Energy Policy and Economics
- Environmental Science and Engineering
- Climate Change Mitigation
Related Concept Videos
Simplified Synchronous Machine Model
The Synchronous Machine Model is a fundamental tool in analyzing and ensuring the transient stability of power systems. This model simplifies the representation of a synchronous machine under balanced three-phase positive-sequence conditions, assuming constant excitation and ignoring losses and saturation. The model is pivotal for understanding the behavior of synchronous generators connected to a power grid, particularly during transient events.
In this model, each generator is connected to a...
In this model, each generator is connected to a...
Energy Conservation and Bernoulli's Equation
Applying the conservation of energy principle or the work-energy theorem to an incompressible, inviscid fluid in laminar, steady, irrotational flow leads to Bernoulli's equation. It states that the sum of the fluid pressure, potential, and kinetic energy per unit volume is constant along a streamline.
All the terms in the equation have the dimension of energy per unit volume. The kinetic energy per unit volume is called the kinetic energy density, and the potential energy per unit volume is...
All the terms in the equation have the dimension of energy per unit volume. The kinetic energy per unit volume is called the kinetic energy density, and the potential energy per unit volume is...
Control of Power Flow
There are several methods to control power flow in power systems:
Maximum Power Flow and Line Loadability
The maximum power flow for lossy transmission lines is derived using ABCD parameters in phasor form. These parameters create a matrix relationship between the sending-end and receiving-end voltages and currents, allowing the determination of the receiving-end current. This relationship facilitates calculating the complex power delivered to the receiving end, from which real and reactive power components are derived.
Reducing Line Loss
In a three-phase circuit, line loss is an indicator of energy dissipated as heat due to the resistance of transmission lines. To address this, incorporating transformers into the system—a step-up transformer at the source and a step-down transformer at the load—is a strategic solution. Two three-phase transformers are introduced to improve this.
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...
Electrical Power
Electric power is the product of current and voltage, represented in units of joules per second, or watts. For example, cars often have one or more auxiliary power outlets with which you can charge a cell phone or other electronic devices. These outlets may be rated at 20 amps and 12 volts, so that the circuit can deliver a maximum power of 240 watts. Consider a 25 Watt bulb and a 60 Watt bulb. The conversion of electrical energy produces heat and light, while the kinetic energy lost by the...