Related Experiment Video
Updated: May 23, 2026

Measurement of Outgassing Rates of Steels
Published on: December 13, 2016
CRITICAL TEMPERATURE OF AXIALLY LOADED STEEL MEMBERS WITH WIDE-FLANGE SHAPES EXPOSED TO FIRE
Ana Sauca1, Rachel Chicchi2, Chao Zhang3
1Post-doc Research Engineer, Danish Institute of Fire and Security Technology, Jernholmen 12 2650 Hvidovre, Denmark, (Former guest researcher at National Institute of Standards and Technology).
None:
This paper presents closed-formed equations that were developed to evaluate critical temperatures of structural steel compression and tension members exposed to fire. The deterministic approach involved a parametric study using finite-element simulations in order to identify influencing factors, e.g., mechanical properties of steel, member slenderness, and axial load ratios. Statistical models were employed to develop closed-form equations representing the best fit of numerical results. A comparison with experimental column test data indicates that the proposed equation for compression members provides a conservative lower bound (16% lower on average) relative to the test data at load ratios greater than 0.3. A sensitivity study was also performed to further explore uncertainty in predicted critical temperatures due to variability of axial load ratios. For both compression and tension members, the ambient-temperature yield stress of steel (F y ) has a greatest impact on determination of axial load ratios, subsequently influencing the overall accuracy of the critical temperature estimated by the proposed equations. The applicability of the proposed equations is limited to wide-flange steel members that are simply supported, concentrically loaded, and exposed to uniform heating.
Related Concept Videos
Unsymmetric Loading of Thin-Walled Members: Problem Solving
To compute the shear forces, find the shear flow at a specific distance from the endpoint using the vertical shear and the moment of inertia values. The total shear force on the flange is calculated by integrating the shear flow from one end of the flange to the other.
Next, calculate the moments of...
Internal Loadings in Structural Members: Problem Solving
To illustrate this, let's consider a beam OC of 5 kN, inclined at an angle of 53.13° with the horizontal and supported at both ends. Determine the internal loadings...
Temperature Dependent Deformation
Unsymmetric Loading of Thin-Walled Members
The concept of the shear center is crucial in countering the...
Mechanical Characteristics of Steel
The tension test is fundamental for determining tensile strength. In this test, a steel specimen is stretched using a gripping device until it breaks. The data collected during this test are used to...
Design of Prismatic Beams for Bending