Intravenous contrast medium impairs CT-based muscle quality but not quantity assessment: a translational study
Luca Salhöfer1,2, Gregor Jost3, Mathias Holtkamp2
1Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen, Germany.
Objectives:
CT-based body composition analysis (BCA) provides imaging biomarkers, including muscle volume and surrogates of muscle quality. Concerns over the comparability of Non-contrast and contrast-enhanced CT scans have limited their clinical application. This study aims to assess the influence of various contrast phases on a volumetric CT-based BCA.
Materials And Methods:
20 Göttingen minipigs were subjected to a Non-contrast (NC) and five contrast-enhanced [Early Arterial, Late Arterial, Vascular Portal Venous, Parenchymal Portal Venous (PPV), Late] CT scans. 114 tri-phasic (Non-Contrast, Arterial, Venous) CT scans were analyzed for human validation. A volumetric BCA network [Body and Organ Analysis (BOA)] extracted muscle radiodensity and the following features as volumes: Muscle, Subcutaneous Adipose Tissue (SAT), Inter- and Intramuscular Adipose Tissue (IMAT), Visceral Adipose Tissue (VAT), and Total Adipose Tissue (TAT). Significance was assessed by a one-way ANOVA with Tukey's multiple comparisons test.
Results:
In the animal model, there was a tendency toward reduced IMAT volumes after CM injection [NC = 245 ml (±105 ml), e.g., PPV = 241 ml (±105 ml)]. Muscle radiodensity was significantly higher following CM administration [Non-contrast: 51.1 HU (±1.9 HU), e.g., Late: 56.6 HU (±2.4 HU), p < 0.001]. The human validation analysis showed similar tendencies for the IMAT volume [Non-contrast: 1750ml (±729 ml), Venous: 1,552 ml (±696 ml), p = 0.10] and significantly higher muscle radiodensity [Venous: 39.2 HU (±9.1 HU), Non-contrast: 35.6 HU (±7.8), p = 0.007].
Conclusion:
Myosteatosis surrogates, such as muscle radiodensity or IMAT, are susceptible to interference by CM, while quantification of muscle tissue and extramuscular fat remains robust.
More Related Videos
08:13In Vivo Quantitative Assessment of Myocardial Structure, Function, Perfusion and Viability Using Cardiac Micro-computed Tomography
Published on: February 16, 2016
08:41Novel In Vivo Micro-Computed Tomography Imaging Techniques for Assessing the Progression of Non-Alcoholic Fatty Liver Disease
Published on: March 24, 2023
Related Concept Videos
Radiological Investigation I: X-ray and CT
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...