Related Experiment Video
Updated: May 28, 2026

Microfluidic Mixers for Studying Protein Folding
Published on: April 10, 2012
Numerical Investigation of a Mitochondria-Inspired Micromixer for Enhanced Mixing
Muhammad Ali Hashmi1, Arvydas Palevicius1, Sigita Urbaite1
1Faculty of Mechanical Engineering and Design, Kaunas University of Technology, 51424 Kaunas, Lithuania.
Abstract:
Today, microfluidics has become a revolutionary field of engineering due to its wide range of applications, including lab-on-a-chip devices, microscale biochemical reactors, drug delivery systems, and disease diagnostics. Efficient fluid mixing has been a significant challenge in these systems due to the dominance of laminar flow and low-Reynolds number conditions, where mixing relies primarily on slow molecular diffusion. It is very difficult to achieve rapid mixing and homogeneous mixing within a limited length. In this study, a bioinspired passive micromixer is developed based on the cristae architecture of mitochondria, which is known for maximizing surface area and transport efficiency in biological systems. The micromixer incorporates cristae-like microstructures within a straight microchannel to produce continuous flow deflection, stretching, and folding, thereby promoting chaotic advection without relying on external energy sources. It also includes mitochondrial granules, such as micropillars, within the channel to disrupt streamline flow. Thus, a numerical investigation was conducted to design four different micromixer geometries: conventional T-channel, and T-channels with a single, double and triple matrix of cristae. The analysis was performed in COMSOL Multiphysics, in which "Laminar flow" and "Transport of diluted species" physics were used, and a stationary study was executed. Simulations were conducted at different Reynolds numbers (Re = 0.1-100) to observe the feasibility of the proposed designs. For analysis, the mixing index and concentration profiles at the outlet and along the length were also examined. The results showed that the high cristae density channel performed well, achieving a mixing index of 95.85% at Re = 0.1 and 85.84% at Re = 100, proving that the proposed mitochondria-inspired cristae Mito-mixer delivers efficient mixing over a broad Reynolds-number range while maintaining a compact, length-efficient design.
More Related Videos
10:12Analyzing Mixing Inhomogeneity in a Microfluidic Device by Microscale Schlieren Technique
Published on: June 12, 2015
08:31One-Step Approach to Fabricating Polydimethylsiloxane Microfluidic Channels of Different Geometric Sections by Sequential Wet Etching Processes
Published on: September 13, 2018