Related Experiment Video
Updated: May 28, 2026

11:34
Subsurface Defect Localization by Structured Heating Using Laser Projected Photothermal Thermography
Published on: May 15, 2017
Acoustic Source Localisation of Crack Initiation During Laser-Based DED: Experimental Validation and Challenges
Md Jonaet Ansari1,2, Elias J G Arcondoulis3, Anthony Roccisano1,2
1Future Industries Institute, Adelaide University, Mawson Lakes, SA 5095, Australia.
Materials (Basel, Switzerland)
|May 27, 2026
Summary
Airborne acoustic source localisation (ASL) can detect cracks during laser-based directed energy deposition (DED-LB/M) manufacturing. This study shows ASL is feasible for in situ crack localisation, though accuracy varies with depth and process complexity.
Area of Science:
- Materials Science and Engineering
- Additive Manufacturing
- Non-Destructive Testing
Background:
- Cracks are critical defects in laser-based directed energy deposition (DED-LB/M) additive manufacturing.
- In situ monitoring is crucial for real-time defect detection and process control.
Purpose of the Study:
- To evaluate the feasibility of airborne acoustic source localisation (ASL) for in situ crack localisation in DED-LB/M.
- To assess the accuracy and limitations of ASL for identifying crack positions during fabrication.
Main Methods:
- Utilised a four-microphone array and Generalised Cross-Correlation with Phase Transform (GCC-PHAT) algorithm.
- Optimised microphone array geometry numerically for industrial constraints.
- Estimated crack positions from acoustic emissions and time differences of arrival (TDOAs).
- Validated results against post-process microscopic measurements.
Main Results:
- Localisation errors varied: X (12-68 mm), Y (0.7-32 mm), Z (5-100 mm).
- Achieved centimetre-scale accuracy for horizontal crack localisation.
- Depth (Z-direction) estimation showed greater variability.
- Confirmed ASL provides spatial information on crack formation.
Conclusions:
- Airborne ASL is industrially feasible for in situ crack investigation in DED-LB/M.
- Performance is sensitive to TDOA accuracy, array constraints, and acoustic environment.
- Further advancements in array design and signal processing are needed for robust 3D defect localisation.