Related Experiment Video
Updated: May 28, 2026

Detecting the Water-soluble Chloride Distribution of Cement Paste in a High-precision Way
Published on: November 21, 2017
Effects of Bending Load Level and Cementitious Capillary Crystalline Waterproofing Content on Chloride Transportation
Yongdong Yan1, Daniel Mishael1, Chunhua Lu1
1Department of Civil Engineering, Jiangsu University, Zhenjiang 212000, China.
Abstract:
The composition and interface quality of jointed concrete can significantly influence chloride ion penetration, especially in coastal environments. This study investigates the transport behavior of chloride ions in concrete flexural members with varying joint configurations-no joint, smooth wet joint, and roughened wet joint-under different bending loads. After 28 days of curing, specimens were subjected to bending loads and immersed in an 8% NaCl solution for 300 days. Chloride ion concentrations were then measured at different depths and locations. Results revealed that joints, particularly smooth wet joints, significantly accelerate chloride ion transmission, and that chloride accumulation at the joint is consistently higher than in adjacent areas or jointless concrete. The apparent diffusion coefficient of chloride ions was notably higher at joint interfaces and increased with bending load level due to microcrack formation. Notably, the incorporation of Cementitious Capillary Crystalline Waterproofing (CCCW) in the concrete mix improved resistance to chloride ion penetration. A dosage of 1% CCCW proved most effective, reducing the diffusion coefficient at the joint by approximately 10%-demonstrating an optimal balance between performance and material efficiency. These findings provide practical guidance for improving the durability of jointed concrete structures in chloride-rich environments.
More Related Videos
10:00Experimental Protocol to Determine the Chloride Threshold Value for Corrosion in Samples Taken from Reinforced Concrete Structures
Published on: August 31, 2017
06:27Expression of Cementitious Pore Solution and the Analysis of Its Chemical Composition and Resistivity Using X-ray Fluorescence
Published on: September 23, 2018
Related Concept Videos
Microcracking in Concrete
Curing of Concrete
Bleeding in Fresh Concrete
Bleeding can cause several issues in the concrete structure. Sometimes, the rising water gets trapped beneath large aggregate...
Types of Cement I
Type I (Ordinary Portland Cement) is widely used for general construction where special properties are not required. It has moderate sulfate resistance and heat of hydration.
Type II (Modified Cement) offers moderate resistance to sulfate attack and a lower rate of heat development compared to Type I. It is suitable for structures in...
Porosity in Cement Paste
The balance of water to cement in the mix is critical—it...
Permeability of Concrete