Related Experiment Video
Updated: May 31, 2026

Non-destructive SPE-UPLC-based Quantification of Aflatoxins and Stilbenoid Phytoalexins in Single Peanut (Arachis spp.) Seeds
Published on: April 19, 2024
A multispectral and LC-MS/MS approach for investigating matrix interference in aflatoxin B1 analysis of pressed
Mohan Li1, Chenhao Jiang1, Dian Zhou2
1College of Food Science, Southwest University, No. 2 Tiansheng Road, Beibei, Chongqing 400715, PR China; Chinese-Hungarian Cooperative Research Centre for Food Science, Chongqing 400715, PR China; Chongqing Key Laboratory of Specialty Food Co-built by Sichuan and Chongqing, Chongqing 400715, PR China.
Abstract:
Pressed peanut cake (PPC) is a valuable plant-based protein source, but its complex matrix might lead to underestimation of aflatoxin B1 (AFB1). This study established a multi-technique diagnostic framework integrating UV-Vis, FTIR, LC-MS/MS, and SEM to systematically dissect matrix interference in different extraction solvents, ultimately correlating with AFB1 detection. It was found that, due to lipid interference, the use of nonpolar solvents during extraction not only significantly amplified detection errors but also severely compromised extraction efficiency, resulting in an analytical error exceeding 85%. Systematic profiling revealed that conventional methanol/water extraction introduced dual errors, attributable to either inefficient toxin extraction or excessive pigment co-extraction, leading to an AFB1 underestimation up to 50%. Acetonitrile/water was identified as the optimal extraction solvent, minimizing interferents and achieving consistent AFB1 recoveries >90%. This work not only provides a practically applicable detection protocol but also offers a clear mechanistic explanation for the observed errors.
More Related Videos
09:44RNAi-mediated Control of Aflatoxins in Peanut: Method to Analyze Mycotoxin Production and Transgene Expression in the Peanut/Aspergillus Pathosystem
Published on: December 21, 2015
07:18Natural Product Discovery with LC-MS/MS Diagnostic Fragmentation Filtering: Application for Microcystin Analysis
Published on: May 31, 2019
Related Concept Videos
MALDI-TOF Mass Spectrometry
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Tandem Mass Spectrometry
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...