Related Experiment Video
Updated: Jun 1, 2026

Multimodal Analytical Platform on a Multiplexed Surface Plasmon Resonance Imaging Chip for the Analysis of Extracellular Vesicle Subsets
Published on: March 17, 2023
A Multitechnique Spectroscopy Platform for Monitoring Heterogeneities in the Higher-Order Structure of mAb
Divya Agrawal1,2,3, Srishti Joshi1, Saxena Nikita1
1Department of Chemical Engineering, Indian Institute of Technology Delhi, New Delhi 110016, India.
None:
Comprehensive characterization of higher-order structure (HOS) is a regulatory prerequisite for monoclonal antibody (mAb) therapeutics, particularly in establishing biosimilarity. A significant analytical challenge lies in detecting the early onset of structural heterogeneity within bulk drug substances, where signal dilution often masks precursor states of degradation. This study proposes a novel, multitechnique spectroscopy platform consisting of UV-vis, Far-UV circular dichroism, intrinsic and extrinsic fluorescence, and Fourier transform infrared (FTIR) spectroscopy coupled with chemometrics for monitoring heterogeneities in HOS during the thermal degradation of trastuzumab, an IgG1mAb therapeutic. While size exclusion chromatography (SEC) confirmed a progressive, monotonic accumulation of soluble aggregates, the proposed multitechnique spectroscopic platform yielded richer information. Intrinsic and extrinsic fluorescence identified an early conformational drift characterized by tertiary core destabilization and hydrophobic exposure immediately upon thermal stress (<1 h), well before the onset of global backbone unfolding detected by circular dichroism. Data fusion via principal component analysis (PCA), biplot, and dendrogram allowed for a more nuanced understanding of the HOS evolution through the thermal stress timeline. The data-fusion approach explained in this study offers a robust, high-resolution framework for monitoring structural consistency through direct HOS mapping, offering a powerful solution for monitoring the quality of biotherapeutic products during stability studies as well as for biosimilarity assessments.
Related Concept Videos
Tandem Mass Spectrometry
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
MALDI-TOF Mass Spectrometry
High-Resolution Mass Spectrometry (HRMS)
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...

