Related Experiment Video
Updated: Jun 5, 2026

Non-invasive 3D-Visualization with Sub-micron Resolution Using Synchrotron-X-ray-tomography
Published on: May 27, 2008
The mantis shrimp eye imaged in 3D using 4th generation synchrotron multiscale phase contrast tomography
Anne Marie Møller Faaborg1, Maja Østergaard1, Nina Kølln Langdal1
1INANO and Department of Chemistry, Aarhus University, 8000 Aarhus, Denmark.
Abstract:
The stomatopod eye is a fascinating biological system capable of detecting both colour and polarization of light, making it a highly complex, mixed-tissue sample. In the investigation of complex biological systems, three-dimensional methods spanning multiple length scales with the power to resolve soft tissues are required. In this study, propagation-based phase contrast X-ray computed tomography with stitching at a 4th generation synchrotron was used to image a full stomatopod eye with sub-micron voxel size to illustrate how this method accommodates these demands. The images are based on natural X-ray contrast and without any added labels or staining agents. Key features of the eye were identified and segmented. Utilizing these segmentations, photo filter volumes, chitin porosity volumes, and muscle fiber periodicities were measured, demonstrating the ability to perform quantitative as well as qualitative investigations. Neural compartments and associated cells were discernable, showing the power of 4th generation synchrotron phase contrast for the study of soft tissues. The illustrated properties along with its non-invasive nature proves phase contrast synchrotron X-ray computed tomography with stitching to be a powerful tool for the investigation of biological materials.
More Related Videos
Related Concept Videos
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Total Internal Reflection Fluorescence Microscopy
Three-Dimensional Microscopy in Microbiology
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...

