Related Concept Videos

Instrument Calibration01:12

Instrument Calibration

Instrument calibration is essential for ensuring that instruments produce accurate and consistent results. It is vital in manufacturing, healthcare, testing laboratories, and scientific research. Calibration processes are specific to each instrument and help enhance data accuracy. Each instrument has a unique calibration process tailored to its design and function to improve data accuracy.
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Calibration Curves: Linear Least Squares01:20

Calibration Curves: Linear Least Squares

A calibration curve is a plot of the instrument's response against a series of known concentrations of a substance. This curve is used to set the instrument response levels, using the substance and its concentrations as standards. Alternatively, or additionally, an equation is fitted to the calibration curve plot and subsequently used to calculate the unknown concentrations of other samples reliably.
For data that follow a straight line, the standard method for fitting is the linear...
Glassware Calibration01:11

Glassware Calibration

Accurate calibration of glassware, such as volumetric flasks, pipettes, and burettes, is essential to ensure accurate measurements in the analytical laboratory. Calibration helps maintain consistency across measurements and prevents errors arising from inaccurate volumes.
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Calibration Curves: Correlation Coefficient01:10

Calibration Curves: Correlation Coefficient

In a linear calibration curve, there is a value called the calibration coefficient, denoted by 'r,' which measures the strength and the direction of association between two variables. The correlation coefficient value ranges from −1 to +1. A value of +1 indicates a perfect positive linear correlation, −1 denotes a perfect negative correlation, and 0 implies no correlation between the two variables. A positive correlation value establishes that as one variable increases, the other increases, and...
Uncertainty in Measurement: Reading Instruments02:46

Uncertainty in Measurement: Reading Instruments

Counting is the type of measurement that is free from uncertainty, provided the number of objects being counted does not change during the process. Such measurements result in exact numbers. By counting the eggs in a carton, for instance, one can determine exactly how many eggs are there in the carton. Similarly, the numbers of defined quantities are also exact. For example, 1 foot is exactly 12 inches, 1 inch is exactly 2.54 centimeters, and 1 gram is exactly 0.001 kilograms. Quantities...
Distance Corrections01:15

Distance Corrections

To achieve precise distance measurements, especially in surveying and construction, certain corrections must be applied to account for potential sources of error like the standardization errors, temperature variations, and slope adjustments.Standardization error emerges when measurement equipment undergoes changes, such as wear, repairs, or weather impacts. To address this, surveyors compare the equipment’s readings to a standard. This process identifies any deviation that might lead to...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Limb remote ischemic post-conditioning mitigates brain recovery in a mouse model of ischemic stroke by regulating reactive astrocytic plasticity.

Brain research·2018
Same author

MicroRNA-411 promoted the osteosarcoma progression by suppressing MTSS1 expression.

Environmental science and pollution research international·2018
Same author

Salidroside provides neuroprotection by modulating microglial polarization after cerebral ischemia.

Journal of neuroinflammation·2018
Same author

Targeting Germinal Matrix Hemorrhage-Induced Overexpression of Sodium-Coupled Bicarbonate Exchanger Reduces Posthemorrhagic Hydrocephalus Formation in Neonatal Rats.

Journal of the American Heart Association·2018
Same author

Megakaryocyte Differentiation and Platelet Formation from Human Cord Blood-derived CD34+ Cells.

Journal of visualized experiments : JoVE·2018
Same author

An ultra-small NiFe<sub>2</sub>O<sub>4</sub> hollow particle/graphene hybrid: fabrication and electromagnetic wave absorption property.

Nanoscale·2018

Related Experiment Video

Updated: Jun 12, 2026

Sit-to-stand-and-walk from 120% Knee Height: A Novel Approach to Assess Dynamic Postural Control Independent of Lead-limb
08:24

Sit-to-stand-and-walk from 120% Knee Height: A Novel Approach to Assess Dynamic Postural Control Independent of Lead-limb

Published on: August 30, 2016

Joint calibration method for a dynamic light-pen measurement system.

Feng Yan, Li Wang, Yaowen Zhu

    Optics Express
    |June 11, 2026
    PubMed
    Summary

    This study introduces a joint calibration framework for dynamic light-pen measurement systems. This method improves 3D measurement accuracy and geometric consistency by addressing coupled parameter errors.

    Area of Science:

    • Metrology
    • Optical Measurement Systems
    • Robotics

    Background:

    • Dynamic light-pen measurement systems use galvanometer cameras for active optical-axis steering, enabling high-resolution imaging during motion.
    • These systems have coupled parameters, leading to calibration errors when parameters are calibrated separately.

    Purpose of the Study:

    • To propose a joint calibration framework for dynamic light-pen measurement systems.
    • To improve the accuracy and consistency of measurements in dynamic environments.

    Main Methods:

    • Developed a regularized consistency-constrained method for joint estimation of galvanometer and probe-tip parameters.
    • Introduced a constrained bundle-adjustment approach for calibrating light pen structural parameters.
    • Enforced cross-view probe-tip consistency to minimize error accumulation.

    More Related Videos

    Determining 3D Flow Fields via Multi-camera Light Field Imaging
    14:25

    Determining 3D Flow Fields via Multi-camera Light Field Imaging

    Published on: March 6, 2013

    Related Experiment Videos

    Last Updated: Jun 12, 2026

    Sit-to-stand-and-walk from 120% Knee Height: A Novel Approach to Assess Dynamic Postural Control Independent of Lead-limb
    08:24

    Sit-to-stand-and-walk from 120% Knee Height: A Novel Approach to Assess Dynamic Postural Control Independent of Lead-limb

    Published on: August 30, 2016

    Determining 3D Flow Fields via Multi-camera Light Field Imaging
    14:25

    Determining 3D Flow Fields via Multi-camera Light Field Imaging

    Published on: March 6, 2013

    Main Results:

    • The joint calibration framework significantly improved geometric consistency.
    • Achieved higher three-dimensional measurement accuracy compared to conventional separate calibration methods.
    • Demonstrated the effectiveness of the proposed methods through experimental validation.

    Conclusions:

    • Joint calibration effectively addresses the challenges posed by coupled parameters in dynamic light-pen systems.
    • The proposed framework offers a more robust and accurate solution for 3D measurement applications.
    • This approach enhances the reliability of dynamic optical measurement systems.