Concomitant Gradient Effects Across Field Strengths and Gradient Amplitudes: Improved Estimation of Errors and
Viktor Olsson1, Felix Mortensen1, Emil Ljungberg1
1Department of Medical Radiation Physics, Lund University, Lund, Sweden.
Purpose:
Deleterious effects from concomitant gradients are amplified at lower field strengths and stronger gradients. We aimed to show the signal errors caused by concomitant gradients across a wide range of hardware configurations and propose corrections that can be applied during experimental design and analysis.
Theory And Methods:
We derived a compact but accurate expression for concomitant gradients and simulated the associated signal bias across field strengths (0.03-7 T) and gradient amplitudes (20-600 mT/m) for asymmetric Maxwell-compensated diffusion encoding gradient waveforms. Bias was assigned to "concomitant dephasing" or "concomitant diffusion weighting." Concomitant dephasing was reduced by waveform correction that was deployed in the design stage. Concomitant diffusion weighting could be accounted for by using the actual gradient waveform during analysis.
Results:
Concomitant dephasing was caused by loss of Maxwell compensation during waveform resampling, with signal errors up to 100%, especially at low B0 and high gmax. Our waveform correction yielded a categorical improvement to signal accuracy, reducing bias to < 1% for most systems. However, bias at extreme B0-gmax-combinations remained > 1% (e.g., B0 = 3 T and gmax = 600 mT/m). Concomitant diffusion weighting caused biases above 1% at across all simulated MRI systems.
Conclusion:
Concomitant gradients have a relevant impact on signal accuracy, especially at low fields and ultra-strong gradients. Concomitant dephasing must be considered for asymmetric waveforms, but can be largely suppressed by our correction method. Concomitant diffusion weighting is always present, regardless of waveform symmetry, but has a smaller impact and can be accounted for in the analysis.
Related Concept Videos
NMR Spectrometers: Resolution and Error Correction
¹H NMR: Interpreting Distorted and Overlapping Signals
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are slanted or...
¹³C NMR: Distortionless Enhancement by Polarization Transfer (DEPT)
Significance of the Gradient Vector
Gradient Fields
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...