Concomitant Gradient Effects Across Field Strengths and Gradient Amplitudes: Improved Estimation of Errors and

Viktor Olsson1, Felix Mortensen1, Emil Ljungberg1

  • 1Department of Medical Radiation Physics, Lund University, Lund, Sweden.

Abstract

Related Concept Videos

NMR Spectrometers: Resolution and Error Correction01:14

NMR Spectrometers: Resolution and Error Correction

When magnetic nuclei in a sample achieve resonance and undergo relaxation, the signal detected in NMR is an approximately exponential free induction decay. Fourier transform of an exponential decay yields a Lorentzian peak in the frequency domain. Lorentzian peaks in an NMR spectrum are defined by their amplitude, full width at half maximum, and position, where the peak width is governed by the spin-spin relaxation time alone. In real experiments, however, the applied magnetic field is rendered...
¹H NMR: Interpreting Distorted and Overlapping Signals01:02

¹H NMR: Interpreting Distorted and Overlapping Signals

Spin systems where the difference in chemical shifts of the coupled nuclei is greater than ten times J are called first-order spin systems. These nuclei are weakly coupled, and their chemical shifts and coupling constant can generally be estimated from the well-separated signals in the spectrum.
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are slanted or...
¹³C NMR: Distortionless Enhancement by Polarization Transfer (DEPT)01:20

¹³C NMR: Distortionless Enhancement by Polarization Transfer (DEPT)

When proton-coupled carbon-13 spectra are simplified by a broadband proton decoupling technique, structural information about the coupled protons is lost. Distortionless enhancement by polarization transfer (DEPT) is a technique that provides information on the number of hydrogens attached to each carbon in a molecule. While the DEPT experiment utilizes complex pulse sequences, the pulse delay and flip angle are specifically manipulated. The resulting signals have different phases depending on...
Significance of the Gradient Vector01:27

Significance of the Gradient Vector

A surface defined by a function of two variables can be understood by examining how it changes along specific directions. When one variable is held constant, the surface reduces to a curve that reflects variation in the other variable. For example, fixing one variable and moving parallel to a coordinate axis produces a cross-sectional curve. The slope of this curve at a given point represents how the function changes in that particular direction, providing a measure of local steepness.By...
Gradient Fields01:27

Gradient Fields

A gradient field is a vector field derived from a scalar field. A scalar field assigns a single numerical value to every point in space, such as temperature, pressure, or electric potential. The gradient field describes how that value changes from point to point. It gives both the direction of the fastest increase and the rate of change in that direction.For a scalar field f(x, y), the gradient is written as\begin{equation*}\nabla f=\left\langle \jfrac{\partial f}{\partial x},\jfrac{\partial...
Effects of EDTA on End-Point Detection Methods01:18

Effects of EDTA on End-Point Detection Methods

Different methods, such as visual observance of metal-ion indicators, spectroscopic techniques, and potentiometric methods, can determine the endpoint of an EDTA titration.
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...