Non-Targeted Hyperspectral Imaging Screening of Adulterants and Congeneric Species in Fritillaria Using a Deep
Zhizhi Huang1, Kai Chen1, Haoyuan Ding1
1College of Optical, Mechanical and Electrical Engineering, Zhejiang A&F University, Hangzhou 311300, China.
Abstract:
Hyperspectral imaging has emerged as a powerful tool for food quality assessment, yet most existing methods rely on supervised classification and require prior knowledge of adulterant categories. This study applies a non-targeted screening approach based on a deep spectral autoencoder to detect adulterants in Fritillaria. While autoencoder-based anomaly detection has been established in other hyperspectral domains, its application to congeneric species discrimination and exogenous adulterant screening in Fritillaria has not been systematically explored. A deep spectral autoencoder was constructed and trained exclusively on pure samples to learn the intrinsic spectral distribution of authentic materials. During inference, reconstruction error was used as an anomaly score, and samples deviating from the learned spectral manifold were identified as suspicious. Spectral data augmentation and band trimming were applied to enhance model robustness, while the anomaly threshold was determined solely from the distribution of pure samples. The proposed method achieved strong discrimination performance, with an area under the receiver operating characteristic curve (AUC) of 0.9903 and high detection rates across multiple adulterant types. Typical exogenous adulterants such as starch and talc powder were completely detected, while congeneric species also showed high detection sensitivity despite their spectral similarity to authentic samples. Latent space visualization and residual spectral analysis further revealed clear separation patterns and interpretable spectral deviations. These results demonstrate the proof-of-concept viability of the proposed non-targeted framework for open-set screening of adulteration risks. However, the authentic samples used for training originated from a single source, and only a limited set of anomaly types was tested. Therefore, the current model should be regarded as an early proof-of-concept only, not as a ready-to-deploy screening tool. Further validation with diverse authentic samples and a wider range of adulterants under realistic variability is necessary before the method can be considered a practical strategy for quality control.