BRICK-Automated Virtual Temperature Sensors for Sensor Fault Detection, Isolation, and Discrimination in
Khaled Chahine1, Hassan N Noura2,3
1College of Engineering and Technology, American University of the Middle East, Egaila 54200, Kuwait.
Abstract:
Sensor bias faults in closed-loop HVAC systems pose a detection challenge that is both subtle and costly. Because the control loop compensates for biased readings by driving the affected sensor back toward its setpoint, the fault becomes invisible to conventional threshold monitors. The anomaly does not vanish, however; it is redistributed across correlated sensors, disrupting their mutual consistency. We propose a framework that automatically derives virtual temperature sensor models from BRICK schema metadata. LightGBM regressors, trained on fault-free inter-sensor relationships, produce z-scored prediction residuals that serve as detection signals. Fault isolation is achieved by ranking sensors by their median daily anomaly scores; fault-type discrimination relies on analysis of actuator command-position discrepancies. On the Lawrence Berkeley National Laboratory (LBNL) fault detection and diagnosis (FDD) benchmark, the method achieves an area under the receiver operating characteristic curve (AUC) of 0.9992 for the mildest sensor bias (SA +2 °C), an AUC of 1.0 for all other single-duct air handling unit (SD-AHU) scenarios, and an AUC of 1.0 for all fan coil unit (FCU) sensor bias scenarios. In all four SD-AHU sensor bias scenarios, the biased sensor (SA_TEMP) ranks first or second; for the larger biases (±4 °C), SA_TEMP consistently ranks first. A robustness analysis over 10 random seeds confirms that detection AUC remains above 0.997 in all cases. Sensor and mechanical faults fall into non-overlapping clusters in the command-position discrepancy space. On the FCU system, the proposed method substantially outperforms principal component analysis (PCA) (AUC = 1.0 versus 0.63-0.90) and provides diagnostic capabilities not available with PCA. Notably, a single pipeline function handles both system types without modification, confirming cross-system scalability through the BRICK metadata layer. The results confirm that BRICK-automated virtual sensor construction is a viable approach for scalable, deployment-ready sensor validation in smart-building HVAC systems.
More Related Videos
Related Concept Videos
Operational Amplifiers
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Refrigerators and Heat Pumps
A household refrigerator removes heat from the...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Bioreactor Controls-I