Related Experiment Video
Updated: Jun 13, 2026

Using a Cell-Tracer Injection to Investigate the Origin of Neointima-Forming Cells in a Rat Saccular Side Wall Model
Published on: March 16, 2022
Aneurysm wall contrast enhancement after coiling: A retrospective cross-sectional study comparing ruptured and
Arndt-Hendrik Schievelkamp1,2, Alexander Schnepper3, Elke Hattingen4
1Department of Neuroradiology, University Hospital Bonn, Rheinische Friedrich-Wilhelms-Universität Bonn, Bonn, Germany. arndt-hendrik.schievelkamp@uk-koeln.de.
Objective:
We aimed to compare aneurysm wall enhancement post-coil embolization between patients with and without subarachnoid hemorrhage (SAH). We hypothesized that ruptured aneurysms in SAH patients exhibit different enhancement patterns compared to incidentally found unruptured aneurysms. To account for potential confounders affecting wall enhancement, coil packing density and aneurysm size were evaluated.
Methods:
This retrospective cross-sectional single-center study included patients who underwent coil embolization for intracranial aneurysms. These patients were monitored with digital subtraction angiography (DSA) and magnetic resonance imaging (MRI), including a contrast-enhanced black-blood sequence. Aneurysm wall enhancement was assessed by ROI-based signal intensity measurements and supplementary visual scoring, and compared between groups using the Student's t-test and Mann-Whitney U test, respectively. In addition, linear and multivariable regression analyses were performed to explore the effects of coil density and aneurysm size on wall enhancement and to assess the independence of the observed group differences.
Results:
Among the 31 patients studied, non-SAH patients showed higher wall signal intensity than SAH patients (ROI measurements: SAH: 813 SI vs. no SAH: 1151 SI, p<0.01; visual assessment showed a consistent trend, p=0.055). Neither coil packing density nor aneurysm size independently predicted wall enhancement, and SAH status remained the only significant independent predictor in multivariable analysis.
Conclusions:
Aneurysm wall enhancement following coil embolization differs significantly between patients with and without SAH. The observed signal differences are preliminary and should be regarded as hypothesis-generating, warranting further investigation in future prospective studies.
Related Concept Videos
Aneurysm II: Clinical Manifestations and Diagnostic Studies
Aneurysm I: Introduction
Aneurysm III: Interprofessional Care
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...