Related Experiment Video
Updated: Jun 18, 2026

A Cognitive Fusion-guided Prostate Biopsy Using Multiparametric Magnetic Resonance Imaging and Transrectal Ultrasound
Published on: March 21, 2025
Combining the PI-RADS v2.1 score with PSAD improves the diagnostic accuracy of transition zone prostate cancer
Jinman Zhong1, Jianke Ding2, Yuelang Zhang1
1Department of Radiology, The Second Affiliated Hospital, Xi' an Jiaotong University, China.
Introduction:
Transition zone (TZ) prostate cancer poses diagnostic challenges due to overlapping imaging features with benign prostatic hyperplasia (BPH). This study aimed to investigate whether Prostate Imaging Reporting and Data System (PI-RADS) v2.1 combined with prostate-specific antigen density (PSAD) can enhance diagnostic accuracy in distinguishing TZ cancer from BPH.
Material And Methods:
The retrospective study included 377 patients divided into two groups: the TZ cancer group (n = 139) and the BPH group (n = 238). Two radiologists independently reviewed prostate MR images of each patient and assigned a PI-RADS score for the TZ lesion. Clinical characteristics were compared between the two groups using the χ2 test, t-test, or Mann-Whitney U-test. The diagnostic performance of PI-RADS scores, PSAD, and the combined parameters was determined by ROC curve analysis.
Results:
Statistically significant differences were found in PSA, prostate volume, PSAD, and PI-RADS scores between the two groups (all p < 0.0001). No difference in age was observed between the two groups (p = 0.602). The area under the curve (AUC) for PI-RADS v2.1 alone was 0.802 (95% CI: 0.759-0.841) with a sensitivity of 79.14% and specificity of 74.37% at a cutoff of ≥ 4. The AUC for PSAD alone was 0.808 (95% CI: 0.765-0.847) with a sensitivity of 79.14% and specificity of 77.31% at a cutoff of 0.22 ng/ml/ml. Combining PI-RADS and PSAD yielded an AUC of 0.873 (95% CI: 0.835-0.905), with a sensitivity of 79.26% and specificity of 86.55%.
Conclusions:
The combination of PI-RADS v2.1 and PSAD enhances the diagnostic accuracy for TZ cancer, thereby reducing unnecessary invasive procedures.
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...

