Standardized MRI-Based Quantification of Epicardial Adipose Tissue Volume: Reproducibility and Agreement With Cardiac
Judith Gronwald1, Svante S Gersch1, Zoé Böttiger1
1Department of Cardiology and Pneumology, University Medical Center Göttingen, Georg-August University and German Center for Cardiovascular Research (DZHK), Partner Site Lower-Saxony, Göttingen, Germany.
Background:
Epicardial adipose tissue volume (EATV) is increasingly recognized as a cardiometabolic risk marker associated with adverse outcomes. The most established approach for EATV quantification is cardiac computed tomography (CT). MRI offers a radiation-free alternative allowing simultaneous assessment of myocardial function and tissue characteristics; however, standardization and validation are limited.
Purpose:
To evaluate a standardized MRI-based method for EATV quantification and determine its agreement with CT.
Study Type:
Retrospective.
Population:
127 patients with aortic stenosis (AS) (78 ± 6 years; 38% female) who underwent paired CT and MRI and 11 volunteers (74 ± 7 years, 45% female) who underwent repeat MRI after ≥ 6 weeks.
Field Strength/Sequence:
Short-axis balanced steady-state free precession cine sequence at 3T (AS patients) and 1.5T (volunteers).
Assessment:
On CT, EATV was quantified by manual delineation of the visceral pericardium and voxel-thresholding (-190 to -30 HU). MRI-based EATV quantification used manual volumetry with delineation of the visceral pericardium and epicardium on end-diastolic short-axis cine stacks.
Statistical Tests:
Inter-modality agreement was assessed by Spearman correlation and Bland-Altman analysis. Reproducibility was evaluated in 20 patients using intraclass correlation coefficient (ICC) and coefficient of variation (CoV). Scan-rescan reproducibility for MRI-derived EATV quantification was assessed using ICC and linear regression. p < 0.05 was considered significant.
Results:
Median EATV was significantly higher on MRI than CT (47 vs. 38 mL/m2), with a significant moderate correlation (ρ = 0.627) between measures. Inter- and intra-observer analyses showed excellent reproducibility for both modalities (CT: intra-observer ICC: 0.983, inter-observer ICC: 0.994; MRI: intra-observer ICC: 0.955, inter-observer ICC: 0.970). MRI-derived EATV quantification also showed excellent scan-rescan reproducibility (ICC: 0.985).
Data Conclusion:
The standardized MRI-based approach enabled highly reproducible EATV measurements with excellent repeatability. Agreement with CT was moderate, with systematically higher values on MRI, limiting direct comparability.
Evidence Level:
3.
Stage Of Technical Efficacy:
2.