Related Experiment Video
Updated: Jun 25, 2026

Predicting Amputation using Local Circulating Mononuclear Progenitor Cells in Angioplasty-treated Patients with Critical Limb Ischemia
Published on: September 22, 2020
Ultrasound to predict radial artery catheterization failure in patients undergoing major cardiovascular surgery
Jerome Paniego1,2, Gudrun Boge3, Marc Mourad1
1Department of Anesthesiology and Critical Care Medicine, Arnaud de Villeneuve, CHU Montpellier, Montpellier, France.
Background:
Radial artery catheterization (RAC) remains challenging, with a high failure rate. This study investigated whether ultrasound-measured radial artery (RA) diameter could predict RAC failure in patients undergoing major cardiac or vascular surgery.
Methods:
Consecutive patients scheduled for major cardiac or vascular surgery were prospectively included. Ultrasound images of the left RA were acquired by one operator, while a second operator, blinded to these images, performed RAC using the palpation method. RAC failure was defined as three or more attempts, a change in operator, or cannulation site. All ultrasound images were subsequently analyzed by an expert vascular physician, also blinded. RA internal diameter and depth were measured. Intra- and inter-observer reproducibility were assessed.
Results:
Of 247 patients, 58 (23%) experienced RAC failure. Absent or weak radial pulse (OR 6.36, 95% CI 2.59-15.65; p < 0.001), female sex (OR 2.55, 95% CI 1.36-4.77; p = 0.003), and wrist circumference <18 cm (OR 1.96, 95% CI 1.08-3.54; p = 0.03) each significantly increased RAC failure risk. The RA internal diameter was significantly smaller in the failure group (1.9 ± 0.4 vs 2.1 ± 0.4 mm, p < 0.01). RA was also deeper in the failure group (3.4 ± 1.6 vs 2.9 ± 1.1 mm, p = 0.05). The area under the curve for RA internal diameter to predict RAC failure was 0.62 (95% CI 0.53-0.70, p = 0.007), with an optimal threshold of 1.8 mm. RAC failure prolonged anesthesia induction and doubled the risk of hematoma (p < 0.001). Intra- and inter-observer agreement for RA internal diameter were excellent (ICC 0.86, 95% CI 0.78-0.92 and 0.94, 95% CI 0.91-0.97, respectively).
Conclusion:
A small RA internal diameter significantly increases RAC failure risk. These findings should inform cannulation site selection, technique, and operator choice to improve procedural success and patient safety.
Related Concept Videos
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Cardiac Catheterization I: Pre-Procedure Overview
Aneurysm IV: Nursing Management
Pre-Procedural Guidelines for Assessing Blood Pressure