Related Experiment Video
Updated: Jun 25, 2026

Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
Comparison of alpha-particle track characteristics in GAGG and biological tissues for microdosimetry using
Kohei Nakanishi1, Seiichi Yamamoto2, Masao Yoshino3
1Biomedical Imaging Sciences, Department of Integrated Health Sciences, Nagoya University Graduate School of Medicine, Nagoya, Japan.
Abstract:
Objective.Real-time imaging of alpha-particle tracks in scintillators is promising for microdosimetric studies of alpha-emitting radionuclides in targeted radionuclide therapy. However, when inorganic scintillators such as Gd3Al2Ga3O12(GAGG) are used, the observed track characteristics differ from those in biological tissues. This study aimed to validate the GATE (geant4 application for tomographic emission) simulation framework using experimentally obtained alpha-particle track images and to compare track characteristics in GAGG and biological tissue-equivalent media. Such analysis is essential for quantitatively interpreting track images obtained with scintillator-based imaging systems in microdosimetry.Approach.Alpha-particle track images were obtained using a real-time high-resolution imaging system based on a GAGG scintillator and an Am-241 source. Simulated track ranges were compared with experimental images. The finalRange parameter in GATE was optimized because it affects the Bragg peak shape of alpha particles. Furthermore, simulated track characteristics in biological tissue-equivalent media were quantitatively compared with those in GAGG.Main Results.A bright endpoint artifact was identified in simulated alpha-particle tracks, originating from the particle transport mechanism implemented in Geant4/GATE and depending on the finalRange value. The simulated and experimental ranges of alpha particles in GAGG were 8.20μm and 8.05μm, respectively, demonstrating good agreement. Linear energy transfer (LET) values in GAGG were 2.8 and 1.8 times higher than those in adipose and bone, respectively.Significance.Recognizing this artifact is important for correct interpretation of LET distributions in microdosimetric evaluations. Our results demonstrated that GATE can accurately reproduce alpha-particle track characteristics and provides a useful framework for interpreting track structures observed in inorganic scintillators in terms of energy deposition in biological tissues. Nevertheless, optimization of the finalRange parameter is required for reliable microdosimetric evaluation.
More Related Videos
06:28Visualization of Low-Level Gamma Radiation Sources Using a Low-Cost, High-Sensitivity, Omnidirectional Compton Camera
Published on: January 30, 2020
10:24Neutron Radiography and Computed Tomography of Biological Systems at the Oak Ridge National Laboratory's High Flux Isotope Reactor
Published on: May 7, 2021
Related Concept Videos
Biological Effects of Radiation
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET