Related Experiment Video
Updated: Jun 26, 2026

Oxygenation-sensitive Cardiac MRI with Vasoactive Breathing Maneuvers for the Non-invasive Assessment of Coronary Microvascular Dysfunction
Published on: August 17, 2022
Adaptive Complex Signal Average Diffusion-Weighted MR Imaging of the Liver: Utility in Breath-Hold Imaging: A
Masahiro Tanabe1, Haruki Furutani1, Miwa Matsukuma1
1Department of Radiology, Yamaguchi University Graduate School of Medicine, 1-1-1 Minami-Kogushi, Ube 755-8505, Japan.
None:
Objectives: This study evaluated the utility of adaptive complex signal average (ACSA) diffusion-weighted imaging (DWI) specifically in breath-hold (BH) liver imaging, with a focus on signal intensity (SI) improvement, intrahepatic signal homogeneity, and apparent diffusion coefficient (ADC) behavior, and compared these findings with conventional non-ACSA DWI and free-breathing (FB) ACSA DWI. Methods: This retrospective study included 62 patients (mean age, 67.8 ± 13.6 years; 27 women) who underwent liver MRI with both FB and BH DWI on a 3-T system. Non-ACSA images were generated using conventional magnitude reconstruction, and ACSA images were reconstructed from identical raw data. SI, signal-to-noise ratio (SNR) and ADC were measured in the left lateral segment and right hepatic lobe. The signal intensity difference ratio (SIDR) between ACSA and non-ACSA, signal intensity ratio (SIR) and ADC ratio between right lobe and lateral segment were calculated. Results: In both FB and BH imaging, SI and SNR in both liver regions were significantly higher on ACSA DWI than on non-ACSA DWI (p < 0.01). ADC values were significantly lower with ACSA. SIDR was significantly higher in the left lateral segment (p < 0.01), indicating greater SI improvement in motion-prone regions. SIR and ADC ratios between lobes were significantly smaller with ACSA in both respiratory conditions (p < 0.01). FB-ACSA showed smaller SIR than BH-ACSA, while ADC ratios did not differ. Conclusions: ACSA DWI significantly improves SI, intrahepatic uniformity, and ADC reliability even under BH liver imaging. BH ACSA DWI may represent a potentially useful application complementary to FB ACSA DWI, supporting its consideration as a post-processing strategy for improving qualitative and quantitative liver DWI in future investigations.
More Related Videos
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Imaging Studies for Cardiovascular System IV: CMRI
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Magnetic Resonance Imaging

