Agreement of WebCeph-Based Automated and Expert-Adjusted Cephalometric Analyses with Manual and Dolphin Tracings
Güray Gürler1, Mustafa Serdar Toroglu1, Oruc Yener Cam2
1Department of Orthodontics, Faculty of Dentistry, Cukurova University, 01330 Adana, Turkey.
Abstract:
Background: This study aimed to compare the measurement agreement and intramethod reliability of four cephalometric analysis workflows: manual tracing, semi-automated digital analysis (Dolphin), fully automated AI-based analysis (WebCeph), and expert-adjusted AI analysis (WebCeph+). Methods: In this retrospective method-comparison study, 67 lateral cephalometric radiographs were initially included. After the exclusion of radiographs containing extreme values, 54 radiographs (35 females, 19 males; mean age: 15.0 ± 2.13 years) were analyzed. Twenty-one skeletal, dental, and soft-tissue parameters (13 angular, 8 linear) were evaluated across the four methods. Intramethod repeatability was assessed via the intraclass correlation coefficient (ICC). Intermethod comparisons were analyzed using ANOVA and post hoc pairwise tests. Pragmatic clinical relevance thresholds were predefined as ±2 degrees for angular measurements and ±2 mm for linear measurements. Results: All methods demonstrated high intramethod reliability, with ICC values exceeding 0.90 in 20 out of 21 parameters. Manual and Dolphin methods yielded statistically comparable results (p > 0.05). In contrast, WebCeph differed significantly from manual and/or Dolphin in seven parameters, including SNA, IMPA, Go-Gn length, Pog to N-perpendicular, Wits appraisal, nasolabial angle, and mentolabial angle (p < 0.05). Several discrepancies exceeded the predefined pragmatic thresholds (±2 degrees and ±2 mm), highlighting their potential clinical relevance. After expert adjustment (WebCeph+), statistically significant inter-workflow differences were no longer observed; however, residual individual-level variability remained for selected parameters. Conclusions: Fully automated WebCeph analysis showed limited agreement with manual and semi-automated methods for several clinically relevant measurements. Expert adjustment reduced systematic mean discrepancies and improved agreement with clinician-dependent workflows; however, residual individual-level variability remained for selected parameters. AI-driven cephalometric analysis should therefore be considered a supportive tool requiring specialist verification rather than an unsupervised replacement for conventional methods.