Abstract:
Objective.This work introduces and validates XrayMC, a novel Monte Carlo (MC) simulation tool specifically designed for photon transport and dose scoring in diagnostic x-ray imaging and image-guided interventional procedures. The tool aims to provide accurate, efficient, and flexible simulations for patient and staff dosimetry in complex imaging environments.Approach.XrayMC implements history-by-history photon transport for energies between 1-150 keV. It supports multiple geometry types such as voxel grids, triangulated surfaces, and tetrahedral meshes, enabling detailed modelling of patients, staff, and imaging equipment. Common x-ray beam configurations used in diagnostic imaging, such as computed tomography (CT), cone beam CT and planar imaging, are included to make it easier to create clinically relevant x-ray beams. XrayMC is benchmarked against the AAPM Task Group 195 MC reference dataset (TG195), with a total of 694 comparisons to reference data across five diagnostic imaging cases, including radiography, mammography, and CT.Main results. All imaging cases relevant to photon transport in TG195 were successfully replicated in XrayMC, and the results from XrayMC are in excellent agreement with those obtained with the TG195 reference MC packages (EGSnrc, Geant4, MCNP, and Penelope). Across all cases, the average deviation from TG195 was less than 0.5%, and 690 of the 694 comparisons between XrayMC and TG195 differed by less than 2%. The largest difference from the TG195 values was 3.6% for energy scored in the adrenals for CT exposures of a voxel phantom.Significance.XrayMC provides a tailored and optimised alternative to general-purpose MC codes for imaging applications. Its flexibility in geometry handling and validated accuracy make it suitable for research and clinical dose assessment, supporting improved radiation protection for patients and healthcare professionals. In addition, XrayMC allows visualisation of dose distributions and simulation set-ups that can aid teaching and understanding of radiation protection in imaging applications.
Related Concept Videos
X-ray Imaging
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Radiological Investigation I: X-ray and CT
X-ray Diffraction of Biological Samples
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are scattered by the electron clouds around the sample atoms. The X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal crystal...
Radiation: Applications
The average...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...