Correction: Resilient distributed model predictive control for cooperative microgrids under communication loss with

    Plos One
    |June 30, 2026
    PubMed
    Summary

    This study corrects a previously published article DOI. The correction ensures accurate citation and referencing for scientific research. Further details are available via the provided DOI.

    Related Concept Videos

    Distributed Loads: Problem Solving01:21

    Distributed Loads: Problem Solving

    Beams are structural elements commonly employed in engineering applications requiring different load-carrying capacities. The first step in analyzing a beam under a distributed load is to simplify the problem by dividing the load into smaller regions, which allows one to consider each region separately and calculate the magnitude of the equivalent resultant load acting on each portion of the beam. The magnitude of the equivalent resultant load for each region can be determined by calculating...
    Distributed Loads01:19

    Distributed Loads

    Distributed loads are a common type of load that engineers and scientists encounter in various practical situations. Distributed loads often refer to a type of load spread over a surface or a structure and can be modeled as continuous force per unit area.
    For example, consider a bookshelf filled with books stacked vertically adjacent to each other. The weight of the books is evenly distributed over the length of the shelf. As a result, the pressure at different locations on the surface of the...
    Line Protection with Impedance Relays01:27

    Line Protection with Impedance Relays

    Coordinating time-delay overcurrent relays in complex radial systems and directional overcurrent relays in multi-source transmission loops can be challenging. Impedance relays address these issues by responding to the voltage-to-current ratio, specifically measuring the apparent impedance of a line. These relays become more sensitive during faults as current increases and voltage decreases, thereby reducing the apparent impedance.
    Under normal conditions, low load currents keep the measured...
    Load-frequency control01:28

    Load-frequency control

    Load-frequency control (LFC) is vital for maintaining power system stability, ensuring that frequency and power flows remain within acceptable limits during load changes. Turbine-governor control eliminates rotor accelerations and decelerations following load changes. However, a steady-state frequency error persists when the change in the turbine-governor reference setting is zero. In an interconnected power system, each area agrees to export or import a scheduled amount of power through...
    Time-Domain Interpretation of PD Control01:07

    Time-Domain Interpretation of PD Control

    Proportional-Derivative (PD) control is a widely used control method in various engineering systems to enhance stability and performance. In a system with only proportional control, common issues include high maximum overshoot and oscillation, observed in both the error signal and its rate of change. This behavior can be divided into three distinct phases: initial overshoot, subsequent undershoot, and gradual stabilization.
    Consider the example of control of motor torque. Initially, a positive...
    Reclosers and Fuses01:26

    Reclosers and Fuses

    Automatic circuit reclosers enhance the protection of distribution circuits by interrupting and auto-reclosing an AC circuit according to a preset sequence. They effectively manage temporary faults on overhead distribution lines, often caused by tree limbs or wildlife, by briefly disrupting service to improve overall reliability. However, contact with reclosers or energized broken conductors on the ground can pose serious hazards.
    A comprehensive protection scheme for radial distribution...