Related Experiment Video
Updated: Jul 2, 2026

Experimental Methods for Investigation of Shape Memory Based Elastocaloric Cooling Processes and Model Validation
Published on: May 2, 2016
Thermal correction method for accurate performance evaluation of micro-thermoelectric coolers
Zhengtao Wang1, Peng Zhao1, Longzhi Wu1
1School of Materials Science and Engineering, and Institute of Materials Genome and Big Data, Harbin Institute of Technology, Shenzhen 518055, People's Republic of China.
Abstract:
The micro-thermoelectric coolers (TECs) with enhanced cooling power density are indispensable for precisely controlling the temperature of optical modules. While the accurate characterization of cooling performance is of paramount importance, a particular difficulty lies in the precise measurement of cooling power for such miniaturized devices. The Harman method and impedance spectroscopy employed for industrial applications are incapable of measuring the cooling power and COP, while the reference sample method will cause significant deviations. Herein, a thermal correction method has been developed to precisely characterize the cooling performance of a micro-TEC. By calibrating the heat losses, the relationship between the input electrical power of the heater and the cooling power of a TEC can be established. It thereby allows the direct measurement of the temperature difference, cooling power, and coefficient of performance (COP) of a TEC at different operating currents. The variation of cooling power and temperature difference across the multiple tests is less than 2.3%, while the variation of cooling temperature difference is less than 1.1%, indicating the high stability and reproducibility of the method. Furthermore, this method has been extended beyond micro-TEC to the measurement of a conventional-size TEC, underscoring the versatility of this technique. Importantly, the accuracy of the characterization has been further verified by comparing the measured COP with the theoretical values. Our work establishes the thermal correction method as a viable technique for the accurate evaluation of the cooling performance of TECs.
Related Concept Videos
Temperature and Thermal Equilibrium
The concept of temperature has evolved from the common concepts of hot and cold. The scientific definition of temperature explains more than just our sense of hot and cold. Temperature is operationally defined as the quantity measured with a thermometer. Furthermore, temperature is...
Thermal expansion and Thermal stress: Problem Solving
To solve the problem, first, identify the known and unknown quantities. The initial length (L) of the bridge is 1275 m, the coefficient of linear expansion (α) for steel is 12 x 10-6/°C, and the change in temperature (ΔT) is 55 °C.